Technical data

266 Agilent N8201A Performance Downconverter Synthetic Instrument Module, 250 kHz to 26.5 GHz
14 Measure (Spectrum Analysis Mode)
n=9 Returns 12 comma-separated scalar values of frequency (in
Hz) that have peak power in each offset (14 when offset F is
active):
1. Reserved for the future use, returns –999.0
2. Reserved for the future use, returns –999.0
3. Negative offset frequency (A)
4. Positive offset frequency (A)
11.Negative offset frequency (E)
12.Positive offset frequency (E)
If offset F is active:
13.Negative offset frequency (F)
14.Positive offset frequency (F)
n=10 Returns 12 comma-separated scalar values (in dBm) of the
absolute peak power of the segment frequencies (14 when
offset F is active):
1. Reserved for the future use, returns –999.0
2. Reserved for the future use, returns –999.0
3. Negative offset frequency (A)
4. Positive offset frequency (A)
11.Negative offset frequency (E)
12.Positive offset frequency (E)
If offset F is active:
13.Negative offset frequency (F)
14.Positive offset frequency (F)
n=11 Returns 12 comma-separated scalar values (in dBc) of the
peak power relative to the carrier at the segment
frequencies (14 when offset F is active):
1. Reserved for the future use, returns –999.0
2. Reserved for the future use, returns –999.0
3. Negative offset frequency (A)
4. Positive offset frequency (A)
11.Negative offset frequency (E)
12.Positive offset frequency (E)
If offset F is active:
13.Negative offset frequency (F)
14.Positive offset frequency (F)
n=12 Returns the band power result when in WLAN standard. If
not in WLAN standard the value returned will be –999.0
n=13 Returns the number of failed trace points
Measurement Results Available (continued)
Command / Condition n Results Returned