Technical data

190 Agilent N8201A Performance Downconverter Synthetic Instrument Module, 250 kHz to 26.5 GHz
9 Input/Output
Key Path: Input/Output, Input Mixer, Ext Mix Band
Remote Command:
Example: MIX:BAND Y
220-325 GHz (J)
Selects J band (mixing harmonic –46). Displays the start and stop frequencies for that
particular band. Other start/stop frequencies are available as long as they are within the
–46 harmonic band.
Key Path: Input/Output, Input Mixer, Ext Mix Band
Remote Command:
Example: MIX:BAND J
User
Lets you define the frequency band for your Input Mixer. The frequencies available depend
on the currently selected harmonic mixing number. Use Mixer Config, Harmonic to select a
particular harmonic number.
Preselected External Mixer Frequency Ranges vs. Harmonic Number
Unpreselected External Mixer Frequency Ranges vs. Harmonic Number
For N positive harmonic mixing band numbers:=
Minimum frequency N 2.9GHz×()321.4MHz+=
Maximum frequency N 6.666GHz×()321.4MHz 650 MHz+=
For N negative harmonic mixing band numbers:=
Minimum frequency N 2.9GHz×()321.4MHz 650MHz+=
Maximum frequency N 6.666GHz×()321.4MHz=
For N positive harmonic mixing band numbers:=
Minimum frequency N 2.9GHz×()321.4MHz+=
Maximum frequency N 6.9GHz×()321.4MHz 650 MHz+=
For N negative harmonic mixing band numbers:=
Minimum frequency N 2.9GHz×()321.4MHz 650MHz+=
Maximum frequency N 6.9GHz×()321.4MHz=