Technical data

Basic Function Commands 8
Agilent N8211A/N8212A Performance Upconverter Synthetic Instrument Module, 250 kHz to 20 / 40 GHz 231
Example
:FREQ:CHAN:BAND DECT
The example sets the frequency band to standard DECT.
*RST BPGS
:FREQuency:CHANnels:NUMBer
Supported All
[:SOURce]:FREQuency:CHANnels:NUMBer <number>
[:SOURce]:FREQuency:CHANnels:NUMBer?
Sets the frequency of the N8211A/N8212A by specifying a channel number of a given
frequency band.
The channel band and channel state must be enabled for this command to work. Refer to
“:FREQuency:CHANnels[:STATe]" on page 232.
Example
:FREQ:CHAN:NUMB 24
The example sets the channel number to 24 for the current band.
*RST +1
PHS Standard PHS as the frequency band.
DECT Standard DECT as the frequency band.
Range Frequency Band Channel
P-GSM Base/Mobile: 1–24
E-GSM and R-GSM Base/Mobile: 1–1023
DCS Base/Mobile: 512–885
PCS Base/Mobile: 512–900
GSM-450 Base/Mobile: 259–293
GSM-480 Base/Mobile: 306–340
GSM-850 Base/Mobile: 128–251
NADC Base/Mobile: 1–1023