Technical data

206 Agilent N8211A/N8212A Performance Upconverter Synthetic Instrument Module, 250 kHz to 20 / 40 GHz
7 System Commands
This example enables bit 0 (decimal 1, Modulation 1 Undermod) and bit 1 (decimal 2,
Modulation 1 Overmod) in the Data Questionable Modulation Negative Transition Filter
register.
Range 0–32767
:QUEStionable:MODulation:PTRansition
Supported All
:STATus:QUEStionable:MODulation:PTRansition <val>
:STATus:QUEStionable:MODulation:PTRansition?
Enables bits in the Data Questionable Modulation Positive Transition Filter register. A
positive transition (0 to 1) of corresponding bits in the Data Questionable Modulation
Condition register will pass through and be read by the Data Questionable Modulation
Event register.
The variable <val> is the sum of the decimal values of the bits that you want to enable.
Refer to the Chapter 4, “Programming the Status Register System for more information on
programming the status registers.
Example
:STAT:QUES:MOD:PTR 3
This example enables bit 0 (decimal 1, Modulation 1 Undermod) and bit 1 (decimal 2,
Modulation 1 Overmod) in the Data Questionable Modulation Positive Transition Filter
register.
Range 0–32767
:QUEStionable:MODulation[:EVENt]
Supported All
This is a destructive read. The data in the register is latched until it is queried. Once queried,
the data is cleared.
:STATus:QUEStionable:MODulation[:EVENt]?
This query returns the decimal sum of the bits in the Data Questionable Modulation Event
register.
Refer to the Chapter 4, “Programming the Status Register System for more information on
programming the status registers.
Range 0–32767