:STATus:QUEStionable:FREQuency:ENABle?
Enables bits in the Data Questionable Frequency Event Enable register. Bits enabled and set
in this register will set the Data Questionable Condition register bit 5.
The variable <val> is the sum of the decimal values of the bits that you want to enable.
Refer to the Chapter 4, “Programming the Status Register System for more information on
programming the status registers.
Example
:STAT:QUES:FREQ:ENAB 7
This example enables bit 0 (decimal 1, Synthesizer Unlocked), bit 1 (decimal 2, 10 MHz
Reference Unlocked), and bit 2 (decimal 4, 1 GHz reference Unlocked) in the Data
Questionable Frequency Event Enable register.
Range 0–32767
:QUEStionable:FREQuency:NTRansition
Supported All
:STATus:QUEStionable:FREQuency:NTRansition <val>
:STATus:QUEStionable:FREQuency:NTRansition?
Enables bits in the Data Questionable Frequency Negative Transition Filter register. A
negative transition (1 to 0) of corresponding bits in the Data Questionable Frequency
Condition register will pass through and be read by the Data Questionable Frequency Event
register.
The variable <val> is the sum of the decimal values of the bits that you want to enable.
Refer to the Chapter 4, “Programming the Status Register System for more information on
programming the status registers.
Example
:STAT:QUES:FREQ:NTR 96
This example enables bit 5 (decimal 32, Sampler Loop Unlocked) and bit 6 (decimal 64, YO
Loop Unlocked) in the Data Questionable Frequency Negative Transition Filter register.
Range 0–32767
:QUEStionable:FREQuency:PTRansition
Supported All