Trapezoid Properties
The following window programs the Trapezoid properties:
Parameter: Description:
Start Voltage (V
0
)
Peak Voltage (V
1
)
Delay (T
0
)
Ramp Up (T
1
)
Peak Width (T
2
)
Ramp Down (T
3
)
End Time (T
4
)
The voltage before and after the trapezoid.
The peak voltage.
The delay after the trigger is received.
The time that the voltage ramps up.
The width of the peak.
The time that the voltage ramps down.
The time V0 persists after the ramp.
Exponential Properties
The following window programs the Exponential properties:
Parameter: Description:
Start Voltage (V
0
)
End Voltage (V
1
)
Delay (T
0
)
Time (T
1
)
Time Constant (T
C
)
The voltage before the waveform.
The ending voltage of the waveform.
The delay after the trigger is received.
Time for the voltage to go from V0 to V1.
The time constant of the curve.