User`s guide

Operating the DC Power Analyzer 3
Model N6705A User’s Guide 47
Ramp Properties
The following window programs the Ramp properties:
Parameter: Description:
Start Voltage (V
0
)
End Voltage (V
1
)
Delay (T
0
)
Ramp Time (T
1
)
End Time (T
2
)
The voltage before the ramp.
The voltage after the ramp.
The delay after the trigger is received.
The time that the voltage ramps up.
The time V1 persists after the ramp.
Staircase Properties
The following window programs the Staircase properties:
Parameter: Description:
Start Voltage (V
0
)
End Voltage (V
1
)
Delay (T
0
)
Step Time (T
1
)
End Time (T
2
)
# of Steps
The voltage before the staircase.
The voltage after the final stair step
(the difference between V0 and V1 is
divided equally between the steps).
The delay after the trigger is received.
The time to complete all staircase steps.
The time V1 persists after the staircase.
The total number of staircase steps.