User`s guide
Quick Reference 1
Model N6705 User’s Guide 21
Arb Preview
Press
Arb
This dialog
displays the
arbitrary
waveforms
that have been
configured.
1
2
3
4
5
6
7
8
9
Arb Preview
1 DC Value This column indicates the present output voltage or current setting that appears at
the output before the Arb is run.
The output will return to this value after the Arb
complete if the Return to DC value box has been checked. If the Last Arb
Value box is checked, the output will remain at the last programmed Arb value.
2 Output
This column identifies the output channel on which the associated waveform will run.
Use the navigation keys to select an output if you wish to select an Arb or edit the Arb
on that output channel.
3 Wave shapes This column illustrates the waveshapes that will run on each output when the
arb(s) are started. Note that all Arbs will run simultaneously.
4
Trigger Source
This dropdown list selects the trigger source for all configured Arbs.
5 Repeat
This column indicates how many times the Arb will repeat if it has been configured to
repeat. If the column is blank, the Arb will only run once.
6
Indicates that the Arb on output 2 runs continuously.
7
3
Indicates that the Arb on output 3 repeats three times.
8 Time
Indicates the time that the longest Arb will run. In this example, all Arbs run the same
amount of time.
9
Close