User`s guide

SCPI Commands Appendix B
Model N6705 User’s Guide 187
SCPI Command Description
SENSe
:CURRent
:CCOMpensate <Bool>, (@chanlist)
Enables/disables the capacitive current compensation
[:DC]:RANGe
[:UPPer] <NRf+>, (@chanlist)
Selects the current measurement range
:AUTO <Bool>, (@chanlist)
Enables/disables measurement autoranging (N6781A, N6782A)
:DLOG
:CURRent
[:DC]:RANGe
[:UPPer] <NRf+>, (@chanlist)
Sets the internal data log current range
:AUTO <Bool>, (@chanlist)
Enables/disables measurement autoranging (N6781A, N6782A)
:FUNCtion
:CURRent <Bool>, (@chanlist)
Enables/disables current data logging
:MINMax <Bool>
Enables/disables min/max data logging
:VOLTage <Bool>, (@chanlist)
Enables/disables voltage data logging
:MARKer<1,2>
:POINt <NRf+>
Positions the data log markers
:OFFSet <NR1>
Sets trigger offset as a percent from start of data log duration
:PERiod <NRf+>
Sets the interval between samples (replaces TINTerval)
:TIME <NRf+>
Sets the duration of the data log in seconds
:TINTerval <NRf+>
Sets the interval between samples (for backward compatibility)
:VOLTage
[:DC]:RANGe
[:UPPer] <NRf+>, (@chanlist)
Sets the internal data log voltage range
:AUTO <Bool>, (@chanlist)
Enables/disables measurement autoranging (N6781A, N6782A)
:ELOG
:CURRent
[:DC]:RANGe
[:UPPer] <NRf+>, (@chanlist)
Sets the external data log current range
:AUTO <Bool>, (@chanlist)
Enables/disables measurement autoranging (N6781A, N6782A)
:FUNCtion
:CURRent <Bool>, (@chanlist)
Enables/disables external current data logging
:MINMax <Bool>, (@chanlist)
Enables/disables external min/max current data logging
:VOLTage <Bool>, (@chanlist)
Enables/disables external voltage data logging
:MINMax <Bool>, (@chanlist)
Enables/disables external min/max voltage data logging
:PERiod <NR1>, (@chanlist)
Sets the integration time of the external data logging
:VOLTage
[:DC]:RANGe
[:UPPer] <NRf+>, (@chanlist)
Sets the external data log voltage range
:AUTO <Bool>, (@chanlist)
Enables/disables measurement autoranging (N6781A, N6782A)
:FUNCtion “VOLTage”|”CURRent” | NONE, (@chanlist)
Enables the measurement function (for backward compatibility)
:CURRent <Bool>, (@chanlist)
Enables/disables current measurements (replaces FUNCtion)
:VOLTage <Bool>, (@chanlist)
Enables/disables voltage measurements (replaces FUNCtion)
:INPut MAIN | AUXiliary, (@chanlist)
Selects the voltage measurement input (only on N6781A)
:HISTogram
:CURRent
[:DC]:BIN
:GAIN? 8 | 0.0039, (@chanlist)
Queries the LSB weight of the histogram (N6781A, N6782A)
:OFFSet? 8 | 0.0039, (@chanlist)
Queries the weight of the histogram (N6781A, N6782A)
:RANGes? (@chanlist)
Queries the values of the bin ranges (N6781A, N6782A)
[:DC]:RANGe
[:UPPer] <NRf+>, (@chanlist)
Sets the measurement range of the histogram (N6781A, N6782A)
:AUTO <Bool>, (@chanlist)
Enables/disables measurement autoranging (N6781A, N6782A)