Specifications

17
DC Power Analyzer Mainframe Key Characteristics
Interface capabilities
GPIB SCPI – 1993, IEEE 488.2 compliant interface
LXI compliance Class C
USB 2.0 Requires Agilent IO Library version M.01.01 or 14.0 and up
10/100 LAN Requires Agilent IO Library version L.01.01 or 14.0 and up
Environmental conditions
Operating environment Indoor use, installation category II (for AC input), pollution degree 2
Temperature range 0 °C to 55 °C (output current is derated 1% per °C above 40 °C ambient temperature)
Relative humidity Up to 95%
Altitude Up to 2000 meters
AC input
Input ratings ~ 100 VAC – 240 VAC; 50/60/400 Hz
Power consumption 1440 VA
Power factor 0.99 @ nominal input and rated power
Net weight
N6705 with 4 modules (typical) 16 kg/35 lbs
Dimensions
Height/width/depth 194.7 mm/425.6 mm/313 mm
7.665 in./16.756 in./12.319 in.