User`s guide
Table Of Contents
- Legal Notices
- Safety Notices
- In this Book
- Contents
- Quick Reference
- Installation
- Operating the Power Supply Locally
- Operating the Power Supply Remotely
- Language Reference
- SCPI Command Summary
- Calibration Commands
- Measure Commands
- Output Commands
- Source Commands
- [SOURce:]CURRent[:LEVel][:IMMediate][:AMPLitude]
|MIN|MAX [SOURce:]CURRent[:LEVel][:IMMediate][:AMPLitude]? [MIN|MAX][SOURce:]CURRent[:LEVel]:TRIGgered[:AMPLitude] |MIN|MAX [SOURce:]CURRent[:LEVel]:TRIGgered[:AMPLitude]? [MIN|MAX] - [SOURce:]CURRent:PROTection:STATe ON|OFF[SOURce:]CURRent:PROTection:STATe?
- [SOURce:]VOLTage[:LEVel][:IMMediate][:AMPLitude]
|MIN|MAX [SOURce:]VOLTage[:LEVel][:IMMediate][:AMPLitude]? [MIN|MAX][SOURce:]VOLTage[:LEVel]:TRIGgered[:AMPLitude] |MIN|MAX [SOURce:]VOLTage[:LEVel]:TRIGgered[:AMPLitude]? [MIN|MAX] - [SOURce:]VOLTage:LIMit:LOW
|MIN|MAX [SOURce:]VOLTage:LIMit:LOW? [MIN|MAX] - [SOURce:]VOLTage:PROTection:LEVel
|MIN|MAX[SOURce:]VOLTage:PROTection:LEVel? [MIN|MAX]
- [SOURce:]CURRent[:LEVel][:IMMediate][:AMPLitude]
- Status Commands
- STATus:PRESet
- STATus:OPERation[:EVENt]?
- STATus:OPERation:CONDition?
- STATus:OPERation:ENABle
STATus:OPERation:ENABle? - STATus:OPERation:NTR
STATus:OPERation:PTR STATus:OPERation:NTR? STATus:OPERation:PTR? - STATus:QUEStionable[:EVENt]?
- STATus:QUEStionable:CONDition?
- STATus:QUEStionable:ENABle
STATus:QUEStionable:ENABle? - STATus:QUEStionable:NTR
STATus:QUEStionable:PTR STATus:QUEStionable:NTR? STATus:QUEStionable:PTR? - *CLS
- *ESE*ESE?
- *ESR?
- *OPC*OPC?
- *SRE*SRE?
- *STB?
- *WAI
- System Commands
- Trigger Commands
- Programming Examples
- Specifications
- Verification and Calibration
- Verification
- Equipment Required
- Measurement Techniques
- Constant Voltage Tests
- Constant Current Tests
- Test Record Form – Agilent N5741A and N5761A
- Test Record Form – Agilent N5742A and N5762A
- Test Record Form – Agilent N5743A and N5763A
- Test Record Form – Agilent N5744A and N5764A
- Test Record Form – Agilent N5745A and N5765A
- Test Record Form – Agilent N5746A and N5766A
- Test Record Form – Agilent N5747A and N5767A
- Test Record Form – Agilent N5748A and N5768A
- Test Record Form – Agilent N5749A and N5769A
- Test Record Form – Agilent N5750A and N5770A
- Test Record Form – Agilent N5751A and N5771A
- Test Record Form – Agilent N5752A and N5772A
- Calibration
- Verification
- Service
- Compatibility
- Index
- Declaration of Conformity

Language Reference 5
Series N5700 User’s Guide 71
Status Commands
Status commands program the power supply’s status registers. As
shown in the following figure, the power supply has three groups of
status registers; Operation, Questionable, and Standard Event. The
Operation and Questionable status groups each consist of the
Condition, Enable, and Event registers and NTR and PTR filters.
LOGICAL
OR
LOGICAL
OR
PON
CME
EXE
DDE
QYE
OPC
0
2
3
4
5
7
1
4
8
16
32
128
1
4
8
16
32
128
EVENT ENABLE
STANDARD EVENT
STATUS
STATUS BYTE
SERVICE
REQUEST
ENABLE
LOGICAL
OR
SERVICE
REQUEST
GENERATION
8
16
32
128
8
16
32
128
RQS
OPER
MSS
ESB
MAV
QUES
4
5
6
7
UNR
OT
OV
0
4
QUESTIONABLE STATUS
10
CONDITION
LOGICAL
OR
EVENT ENABLE
PTR/NTR
1
16
1024
1
16
1024
1
16
1024
1
16
1024
3
CONDITION
5
8
PTR/NTR EVENT
ENABLE
CV
CC
32
256
OC
1
WTG
OPERATION STATUS
PF
2
44
2
4
4
2
22
INH
9
512
512
512
512
64
10
1024
256
1024
256
1024
256
1024
OUTPUT BUFFER
QUEUE
NOT
EMPTY
Data
Data
Data
*STB?
*SRE<n>
*SRE?
*ESR?
STAT:QUES:COND?
*ESE<n>
*ESE?
STAT:QUES:PTR |:NTR <n>
STAT:QUES:PTR |:NTR ?
STAT:QUES:EVEN?
STAT:QUES:ENAB <n>
STAT:QUES:ENAB
STAT:OPER:COND?
STAT:OPER:EVEN?
STAT:OPER:ENAB <n>
STAT:OPER:ENAB
STAT:OPER:PTR |:NTR <n>
STAT:OPER:PTR |:NTR ?
32 32
32
ERROR QUEUE
QUEUE
NOT
EMPTY
Err
Err
Err
44
2
ERROR