User`s guide
User’s Guide 17
U3025AE10 System Setup E8363B/C, E8364B/C, or N5230A/C
12-Port RF Cable Connections
Figure 10 on page 18 illustrates the setup configuration of the U3025AE10 Multiport Test
Set and how it should be configured to the E8364B/C 2-Port and N5230A/C PNA Network
Analyzer.
1. Connect the RF cables supplied with this option between the network analyzer and the
U3025AE10 Test Set. Torque each cable to 8 in-lb. Refer to Table 8 and Figure 10 on
page 18.
CAUTION Each end of the interconnect RF cables have a different length from the bend.
When connecting the RF Interconnect cables be sure that the longer end from
the bend is connected to the PNA.
CAUTION Over torque will cause damage to the test set and may cause connectors to
spin or become loose.
Table 8 12-Port Cable Connection
RF Cables From (PNA) To (Test Set)
U3025-20044 SOURCE OUT SOURCE OUT
U3025-20044 CPLR THRU CPLR THRU
U3025-20045 CPLR ARM CPLR ARM
U3025-20045 RCVR A IN, B IN A IN, B IN