User`s guide

Load Monitor
Statistics: T1/E1
318 5967–9446
Time Graph,
continued
Severely Errored
Seconds
Number of seconds for which any of the
following occurred:
ESF signals with one of the following:
320 or more Path Code Violations, one
or more Out of Frame Defects, an
Alarm Indication Signal Defect.
E1-CRC signals with one of the follow-
ing: 832 or more Path Code Violations,
one or more Out of Frame Defects.
E1-noCRC signals with one of the fol-
lowing: 2048 or more Line Coding Vio-
lations.
D4 signals with one of the following:
One-second intervals with Framing
Error Events, Out of Frame Defect,
1544 or more Line Coding Violations.
Not incremented during an unavailable
second.
State Changes The number of times the PVC when
from an Up state to a Down state or vice
versa.
TS16 Alarm
Indication
Signal Failures
E1 only. Number of times when time-
slot 16 is received as all ones for all
frames of two consecutive multiframes.
Table 32 Load Monitor Statistics: T1/E1, continued
Fr. Relay.
FR PVC
PPP
Statistic Description