User`s guide
Internetwork Monitor
Controlling the Data in the View
192 5967–9446
You can choose from the following time modes.
Delta Displays data values for the period between the last update and the
current update.
Usually, this period is the same as the value specified in the Update
Frequency field. However, the first display after starting the
application or applying changes to the properties will show data values
from the earliest time available to the current time. After the first
update, the view will reflect the Delta setting.
Time mode Delta is relevant only when viewing live data; it is not
available for archive files.
Since Displays data values for the period between the time specified in the
Start Time field and the current time. The specified start time will be
adjusted earlier as needed to match a collection interval boundary.
When you select time mode Since, the earliest time for which
information is available is entered into the Start field. If you specify a
time prior to the earliest time, the earliest time is automatically used.
Earliest Displays data values from the earliest point at which data sources can
provide data.
Range Displays data values for the time range specified with the Start Time
and End Time fields.
When you select time mode Range, the earliest and latest available
value are entered into the Start Time and End Time fields. If you
specify a start time prior to the earliest available time or an end time
later than the latest available time, the available times are
automatically used.
Incremental Displays data values for the collection interval specified in the Interval
field.
Paused Disables data updates, effectively freezing the screen with the current
traffic values displayed.