:MEASure:EMASk(*):PARameter:WIDth:CUStom
:MEASure:EMASk(*):PARameter:WIDth:CUStom
:MEASure:EMASk(*):PARameter:WIDth:CUStom?
Input parameter for the eye width calculation. The valid range is between 1 and
100. In this case 50% is in the middle of the eye in the vertical direction.
A number (percentage) which will be used to calculate the width of the eye.
A number which will be the width of the eye.
:MEASure:EMASk(*):PARameter:HEIght
:MEASure:EMASk(*):PARameter:HEIght
:MEASure:EMASk(*):PARameter:HEIght?
Input parameter for the eye height calculation. The valid range is between 1 and
100. In this case 50% is in the middle of the eye in the horizontal direction.
A number (percentage), which will be used to calculate the height of the eye.
A number, which was set using the command.
:MEASure:EMASk(*):PARameter:PERsistence
:MEASure:EMASk(*):PARameter:PERsistence
:MEASure:EMASk(*):PARameter:PERsistence?
Defines the measurement persistence in seconds.
Time in seconds. 2147483647 is used for infinite persistence.
Time in seconds.
SCPI Command Reference 5
Agilent J-BERT N4903B High-Performance Serial BERT 399
Syntax
Description
Input
Output
Syntax
Description
Input
Output
Syntax
Description
Input
Output