Technical data

MEAS:FEMask(*):PARameter:POINt:NUMBer
MEAS:FEMask(*):PARameter:POINt:NUMBer?
Specifies/returns the number of data points to be measured. The maximum number
of data points is 32.
MEAS:FEMask(*):FETC:DATA[:VALUE]?
IAgilentN490xEDFastEye.GetResults()
MEAS:FEMask(*):FETC:DATA[:VALUE]? nItems
Returns a comma-separated list of measured values for nItems data points. If fewer
points are available, only the values for available points are returned.
The list has the following parameters:
First value returned is number of data points actually returned.
Second value is a flag that indicates whether still more points are available.
For each returned measurement point, 7 values are returned:
dDelay: Delay (data type: NR3).
dThreshold: Value for the bit error rate threshold (data type: NR3).
dComparedBits: Number of compared bits (data type: NR3).
dErroneousBits: Number of errors (data type: NR3).
dErroneousZeros: Number of errors from zeros (data type: NR3).
dErroneousOnes: Number of errors from ones (data type: NR3).
bExtrapolatedFlag: Flag 0 or 1 indicating if the data was calculated or
extrapolated by the firmware server.
MEAS:FEMask(*):FETC:DATA:RELative?
IAgilentN490xEDFastEye.GetRelativeResults()
MEAS:FEMask(*):FETC:DATA:RELative? nItems
5 SCPI Command Reference
350 Agilent J-BERT N4903B High-Performance Serial BERT
Syntax
Description
IVI-COM Equivalent
Syntax
Description
IVI-COM Equivalent
Syntax