Name Description under
:SFError:CBER:MODe[?] “SENSe[1]:SFError:CBER:MODe[?]” on
page 269
:SFError:RESult[?] “SENSe[1]:SFError:RESult[?]” on page
269
SENSe[1]:SFError:FSYMbols[?]
SENSe[1]:SFError:FSYMbols
SENSe[1]:SFError:FSYMbols?
For example;
SENS1:SFE:FSYM "K28.1,K28.1"
This command sets the filler symbols for the error detector's Data.
Filler Primitives are inserted or deleted for clock tolerance compensation. These
are not compared and therefore cannot be counted as errors. Filler Primitives
contain filler symbols. A maximum of 4 alternative filler primitives can be used.
Each filler primitive can consist of upto 4 filler symbols. Filler symbols are separated
by a comma (,).
Example: For SAS we have 4 filler primitives each consisting of 4 filler symbols.
K28.5,D10.2,D10.2,D27.3
K28.5,D7.0,D7.0,D7.0
K28.5,D1.3,D1.3,D1.3
K28.5,D27.3,D27.3,D27.3
This query returns the present values.
SENSe[1]:SFError:CFACtor[?]
SENSe[1]:SFError:CFACtor
SENSe[1]:SFError:CFACtor?
For example;
SENS1:SFE:CFAC 10