Technical data
SENSe[1]:PATTern:TRACk[?]
IAgilentN490xEDDataIn.TrackingEnabled (not IVI-compliant)
SENSe[1]:PATTern:TRACk 0 | 1 | OFF | ON
SENSe[1]:PATTern:TRACk?
This command enables and disables the error detector pattern tracking. When
pattern tracking is enabled, the following commands sent to either the pattern
generator or error detector are sent to both:
• SOURce[1] | SENSe[1] :PATTern:SELect[?]
• SOURce[1] | SENSe[1] :PATTern:FORMat[?]
• SOURce[1] | SENSe[1] :PATTern:MDENsity[:DENSity][?]
• SOURce[1] | SENSe[1] :PATTern:ZSUBstitut[:ZRUN][?]
The query returns the current state of the pattern track setting.
When pattern tracking is disabled, both instruments continue to use the current
settings. Enabling pattern tracking causes the error detector to take over the
settings of the pattern generator.
N O T E
Pattern tracking cannot be used in combination with user-defined sequences which
generate up to four patterns and loops. Maintaining user-defined sequences is a
feature of the pattern generator (see also “[SOURce[1]]:PATTern:SEQuence:DATA
[?] ” on page 112). Pattern tracking is automatically disabled when a user-defined
sequence is enabled.
SENSe[1]:PATTern:CAPTure
SENSe[1]:PATTern:CAPTure filename|Length|Description
File name:File where the captured data is stored as a standard pattern file.
Length:The captured pattern length in bits.
Description:a description for the captured pattern.
SENSe[1]:PATTern:ZSUBstitut[:ZRUN][?]
IAgilentN490xEDDataIn.ZeroSub (not IVI-compliant)
5 SCPI Command Reference
252 Agilent J-BERT N4903B High-Performance Serial BERT
IVI-COM Equivalent
Syntax
Description
Syntax
Description
IVI-COM Equivalent