Technical data

Table 39
Name Description under
:COUPling[?] “OUTPut[5]:COUPling[?] ” on page 190
:TERMination[?] “OUTPut[5]:TERMination[?] ” on page
190
:EIDLe[:STATe] “OUTPut[5]:EIDLe[:STATe]” on page
191
:DATA:XOVer[?] “OUTPut[5]:DATA:XOVer[?] ” on page
191
OUTPut[5]:COUPling[?]
IAgilentN490xPGOutput.TerminationEnabled (IVI-compliant)
OUTPut[5]:COUPling AC | DC
OUTPut[5]:COUPling?
The command enables or disables the source of the termination voltage:
DC: Enables the termination voltage
AC: Disables the termination voltage
The query returns the current state.
OUTPut[5]:TERMination[?]
IAgilentN490xPGOutVoltage.VTermination (IVI-compliant)
OUTPut[5]:TERMination <NR3>
OUTPut[5]:TERMination?
This command sets the data termination level of the pattern generator's Data Out
port. The response form returns the data termination level.
5 SCPI Command Reference
190 Agilent J-BERT N4903B High-Performance Serial BERT
IVI-COM Equivalent
Syntax
Description
IVI-COM Equivalent
Syntax
Description