Technical data
SOURce3:TRIGger:UPATtern<n>
IAgilentN490xPGPosition.Bit (not IVI-compliant)
SOURce3:TRIGger:UPATtern<n> <NR1>
SOURce3:TRIGger:UPATtern<n>?
The command selects a bit position within the user pattern at which the trigger
pulse is to be output for user patterns. The parameter <NR1> must be in the range
of 0 through pattern length - 1.
The response returns the current bit position within the user pattern at which the
trigger pulse is generated.
SOURce3:TRIGger:VOLTage[:LEVel][:IMMediate][:AMPLitude][?]
IAgilentN490xPGTrigVoltage.VAmplitude (IVI-compliant)
SOURce3:TRIGger:VOLTage [:LEVel][:IMMediate][:AMPLitude] <NR3>
SOURce3:TRIGger:VOLTage [:LEVel][:IMMediate][:AMPLitude]?
The command sets the peak to peak value of the Clock Out signal in units of Volts.
The query returns the peak to peak value of the Clock signal in units of Volts.
SOURce3:TRIGger:VOLTage[:LEVel][:IMMediate]:HIGH[?]
IAgilentN490xPGTrigVoltage.VHigh (IVI-compliant)
SOURce3:TRIGger:VOLTage[:LEVel][:IMMediate]:HIGH <NR3>
SOURce3:TRIGger:VOLTage[:LEVel][:IMMediate]:HIGH?
The command sets the DC high output level of the pattern generator's Clock Out
port in Volts. The query returns the DC high output level of the pattern generator's
Clock Out port in Volts.
SOURce3:TRIGger:VOLTage[:LEVel][:IMMediate]:LOW[?]
IAgilentN490xPGTrigVoltage.VLow (IVI-compliant)
5 SCPI Command Reference
180 Agilent J-BERT N4903B High-Performance Serial BERT
IVI-COM Equivalent
Syntax
Description
IVI-COM Equivalent
Syntax
Description
IVI-COM Equivalent
Syntax
Description
IVI-COM Equivalent