Technical data
The default is set to have a length of 128 bits for each half pattern; all bits are set
to zero and the trigger is set to occur on the A/B changeover. See “Working with
User Patterns in SCPI” on page 63 for information on using this command.
[SOURce[1]]:PATTern:UPATTern Subnode
This subnode has the following SCPI structure:
[SOURce[1]:]
:PATTern
:UPATtern<n>
[:LENGth][?]
:LABel[?]
:USE[?]
:DATA[?]
:IDATa[?]
This subnode has the following commands:
Table 25
Name Description under
[:LENGth][?] “[SOURce[1]]:PATTern:UPATtern<n>
[:LENGth][?] ” on page 125
:LABel[?] “[SOURce
[1]]:PATTern:UPATtern<n>:LABel[?] ”
on page 125
:USE[?] “[SOURce
[1]]:PATTern:UPATtern<n>:USE[?] ” on
page 125
:DATA[?] “[SOURce
[1]]:PATTern:UPATtern<n>:DATA[?] ”
on page 126
:IDATa[?] “[SOURce
[1]]:PATTern:UPATtern<n>:IDATa[?] ”
on page 128
5 SCPI Command Reference
124 Agilent J-BERT N4903B High-Performance Serial BERT