Technical data

Waveform Commands 32
Agilent Infiniium 90000 Series Oscilloscopes Programmer's Reference 909
:WAVeform:XUNits?
Query :WAVeform:XUNits?
The :WAVeform:XUNits? query returns the X- axis units of the currently
selected waveform source. The currently selected source may be a channel,
function, or waveform memory.
Returned Format
[:WAVeform:XUNits] {UNKNown | VOLT | SECond | CONStant | AMP | DECibels
| HERTz | WATT}<NL>
Example This example returns the X-axis units of the currently selected waveform
source to the string variable, strUnit, then prints the contents of the
variable to the computer's screen.
Dim strUnit As String ' Dimension variable.
myScope.WriteString ":WAVEFORM:XUNITS?"
strUnit = myScope.ReadString
Debug.Print strUnit