Agilent Infiniium 90000 X-Series Oscilloscopes Data Sheet Combining deep logic analysis with the industry’s highest performance oscilloscope Featuring the world’s fastest mixed signal oscilloscope
Engineered for 33 GHz true analog bandwidth that delivers: Need bandwidth? When you’re deploying leading edge high-speed serial bus designs like FibreChannel, SAS 12 G, or 10 Gb Ethernet KR, jitter matters and picoseconds count. When you’re doing spectral analysis of wide-bandwidth RF signals or investigating transient phenomena, bandwidth is critical. You need the most accurate real-time oscilloscope you can get.
Engineered for 33 GHz true analog bandwidth that delivers: The industry’s highest real-time scope measurement accuracy. When you’re designing with faster signals, shrinking eyes and tighter jitter budgets errors introduced by your oscilloscope can seriously impact your design margins. The Agilent Infiniium 90000 X-Series scopes deliver the highest measurement accuracy available by offering the following characteristics: • True analog bandwidth to 33 GHz • Lowest oscilloscope noise floor (2.
Engineered for 33 GHz true analog bandwidth that now combines deep logic analysis with the industry’s highest performance oscilloscope: 33 GHz true analog bandwidth of the oscilloscope and 80 GSa/s sample rate provides ultra-low noise. Capture your longest signal with up to 25 ms data using 2 Gpt of acquisition memory at 80 GSa/s. See your signal more clearly with a 12.1-inch XGA (1024 x 768) high-resolution color touch screen display.
Featuring bandwidths from 13 to 33 GHz 10 MHz reference clock can be input to or output from the scope to allow precise timebase synchronization with more than one oscilloscope, RF instruments or logic analyzers. Dedicated single acquisition button provides better control to capture a unique event. Customizable multipurpose key gives you any five automated measurements with a push of a button.
Engineered for 33 GHz true analog bandwidth that delivers: The Oscilloscope: highest real-time scope measurement accuracy Whether you’re deploying emerging high speed bus technology, identifying spectral content of wide-bandwidth RF signals, or analyzing transient physical phenomena, you need the truest representation of your signals under test. Agilent invested in leading edge technology to bring you the highest real-time oscilloscope measurement accuracy available today.
Low real-time oscilloscope jitter measurement floor, just got lower (now 100 fs) Oscilloscope bandwidth allows signal rise times to be more accurately depicted. The oscilloscope noise floor directly impacts the y-axis voltage placement of each signal data point. The Infiniium 90000 X-Series scopes combine superiority in these characteristics with extremely low sample clock jitter (< 100 femptoseconds).
Engineered for 33 GHz true analog bandwidth that delivers: The Industry’s Fastest Mixed Signal Oscilloscope A mixed signal oscilloscope integrates traditional analog channels with 16 digital channels In 1996, Agilent pioneered the mixed signal oscilloscope Innovative IC technology we called ‘MegaZoom,’ which delivered highly responsive deep memory so designers can see both cause and effect in digitally controlled analog phenomena.
Engineered for 33 GHz true analog bandwidth that delivers: Industry’s first 30 GHz oscilloscope probing system To take advantage of your investment in a high-bandwidth oscilloscope, you must have a probing system that can deliver bandwidth to the probe tip.
Analysis tools: PrecisionProbe (option 001) Turn your 90000 X-Series oscilloscope into a time-domain transmissometry (TDT) and quickly characterize and compensate any input into your scope. PrecisionProbe technology turns your oscilloscope into the ultimate characterization tool. Not only can you do the normal de-embedding through InfiniiSim, PrecisionProbe allows quick characterization of your entire probe system (including cables and switches) without the need for extra equipment.
Analysis tools: EZJIT, EZJIT + and SDA (standard on DSA models) Gain insight into the causes of signal jitter to ensure high reliability of your design With faster edge speeds and shrinking data-valid windows in today’s highspeed digital designs, insight into the causes of jitter has become critical for success. Using EZJIT and EZJIT + jitter analysis software the 90000 X-Series oscilloscopes help you identify and quantify jitter components that affect the reliability of your design.
Analysis tools: EZJIT Complete (standard on DSA models) Discover signal anomalies to the noise of the waveform More than your standard jitter package In order to efficiently determine root cause for any type of signal degradation in the amplitude domain, you must first determine whether the problem is caused by random or deterministic sources.
Analysis tools: InfiniiSim (options 013 and 014) The most advanced waveform transformation software helps you render waveforms anywhere in a digital serial data link InfiniiSim waveform transformation toolset provides the most flexible and accurate means to render waveforms anywhere in a digital serial data link.
Analysis tools: Serial data equalization (option 012) Significantly reduce receiver errors by opening even tightly shut eyes through equalization emulation Serial data equalization for the 90000 X-Series provides fast and accurate equalization using decision feedback equalization (DFE), feed-forward equalization (FFE), and continuoustime linear equalization (CTLE) modeling in real time. Serial data equalization software allows you to input your own self-designated tap values to verify your design.
Analysis tools: N8900A InfiniiView oscilloscope analysis software View and analyze away from your scope and target system Ever wish you could do additional signal viewing and analysis away from your scope and target system? Now you can. Capture waveforms on your scope, save to a file, and recall into Agilent’s InfiniiView application. View and analyze anywhere your PC goes Take advantage of large high-resolution and multiple displays found in your office.
Analysis tools: User-defined function (option 065) Combine Infiniium and MATLAB for even more analysis Enhance the 90000 X-Series with a seamless gateway to powerful MATLAB analysis functionality. User-defined function software adds new analysis capabilities to the 90000 X-Series, beyond traditional math/analysis features. Now you have the freedom to develop your own math functions or filters using MATLAB and its Signal Processing Toolbox.
Compliance and automated testing Today’s demanding environment means you have much less time to understand the intricacies of the technologies you are testing. You also have less time to develop and test automation software that is designed to increase measurement throughput and decrease time to market. Agilent’s compliance applications save you time and money with measurement automation built into the compliance application.
Compliance and automation testing: Switch matrix support Comprehensive testing, eastily achieved Eliminate reconnections (reducing errors) Compliance applications on Agilent’s 90000 X-Series now support a switch matrix, making testing simple by automating test for each lane of a multi-lane bus. Typical testing requires reconnecting the oscilloscope each time that you switch a lane, which causes wasted time and inaccuracies.
Compliance and automation testing: User-defined application (option 040) Custom automation for your 90000 X-Series oscilloscope The user-defined application is the only fully-customizable automated environment made for an oscilloscope by an oscilloscope designer. It provides full automation, including the ability to control other Agilent instruments, external applications such as MATLAB and your DUT software. Simplify your automation The user-defined application (UDA) makes automation simple.
Compliance and automation testing: Other options on 90000 X-Series oscilloscopes In the previous pages we have highlighted a few of the key technologies that benefit from the industry’s most accurate oscilloscope. The 90000 X-Series offers more than 20 compliance applications, and the list continues to grow. All applications are fully compatible with InfiniiSim, PrecisionProbe and UDA’s unique add-in capability.
Protocol and triggering: Memory support (standard feature on the MSOX) DDR2, 3, and 4 protocol and triggering Because of the introduction of MSO models on the 90000 X-Series, these oscilloscopes now support full protocol and triggering for DDR2, 3 and 4 technologies. The 90000 X-Series allows for full triggering on the following events: read, write, activate, precharge, and many more common memory commands.
Protocol analysis 90000 X-Series oscilloscopes come with more than 15 protocol decoders, including the industry’s only 64/66b decoder. The 90000 X-Series protocol tools feature time-correlated markers that let you easily move between the listing window and the waveform. Protocol tools can be used on up to four lanes simultaneously. These unique tools feature search and trigger capability that lets you scan through the waveform to find the trigger condition that interests you.
Agilent Infiniium Oscilloscope Portfolio Agilent’s Infiniium oscilloscope lineup includes bandwidths from 600 MHz to 63 GHz. Use the following selection guide to determine which best matches your specific needs. All Infiniium real-time oscilloscopes feature the following: • World’s highest bandwidth on 4 channels in a single frame • Industry’s lowest noise floor • Full PrecisionProbe compatibility 9000 Series Up to 4 GHz Available bandwidths 600 MHz, 1 GHz, 2.
Engineered for 33 GHz true analog bandwidth that delivers Configure your high performance real-time oscilloscope solution today Get the most out of your oscilloscope investment by choosing options and software to speed your most common tasks. Configure your Infiniium X-Series oscilloscope in three easy steps. Use option numbers when ordering at time of purchase. Use model numbers to add to an existing scope. 1.
Engineered for 33 GHz true analog bandwidth that delivers Configure your high performance real-time oscilloscope solution today 1.
Engineered for 33 GHz true analog bandwidth that delivers Configure your high performance real-time oscilloscope solution today 3.
Engineered for 33 GHz true analog bandwidth that delivers Configure your high performance real-time oscilloscope solution today Upgrade your oscilloscope after purchase Bandwidth upgrades N5471M 13 GHz to 16 GHz Bandwidth upgrade N5471G 16 GHz to 20 GHz Bandwidth upgrade N5471H 20 GHz to 25 GHz Bandwidth upgrade N5471I 25 GHz to 28 GHz Bandwidth upgrade N5471J 28 GHz to 33 GHz Bandwidth upgrade Memory upgrades N2810A-050 Upgrade 20 Mpts/ch to 50 Mpts/ch memory N2810A-100 Upgrade 50 Mpts/ch to
Infiniium 90000 X-Series Oscilloscopes Performance characteristics Vertical Input channels Four Analog bandwidth (–3 dB)*, 2 channel 2 channel* 4 channel 91304A 13 GHz 13 GHz 13 GHz 91604A 16 GHz 16 GH 16 GHz 92004A 20 GHz 20 GHz 16 GHz 92504A 25 GHz 25 GHz 16 GHz 92804A 28 GHz 28 GHz 16 GHz 93204A 33 GHz 32 GHz 16 GHz Rise time/fall time 10 - 90% 20 - 80% 91304A 32 ps 23 ps 91604A 28.5 ps 21.5 ps 92004A 20 ps 15 ps 92504A 17.5 ps 13 ps 92804A 14.4 ps 11 ps 93204A 12.
Infiniium 90000 X-Series Oscilloscopes Performance characteristics Vertical: digital channels On all MSO models Input channels 16 digital channels Threshold groupings 2 individual threshold settings (1 for channels 0-7 and 1 for channels 8-15) Threshold selections TTL (1.4V), CMOS, (2.5V), ECL (-1.3V), PECL (3.7V), user defined (±3.
Infiniium 90000 X-Series Oscilloscopes Performance characteristics Acquisition Maximum real-time sample rate 91304A 91604A (2 channels) 80 GSa/s 80 GSa/s 80 GSa/s 80 GSa/s 80 GSa/s 80 GSa/s (4 Channels) 40 GSa/s 40 GSa/s 40 GSa/s 40 GSa/s 40 GSa/s 40 GSa/s Memory depth per channel Standard 92004A 92504A 92804A 93204A 20 Mpts on 4 channels 40 Mpts on 2 channels Option 050 50 Mpts on 4 channels (standard on DSA models) 100 Mpts on 2 channels Option 100 100 Mpts on 4 channels 200
Infiniium 90000 X-Series Oscilloscopes Performance characteristics Hardware trigger Sensitivity Edge trigger bandwidth Internal low: 2.0 div p-p 0 to 22 GHz Internal high: 0.3 div p-p 0 to 18 GHz, 1.0 div p-p 0 to 22 GHz Auxiliary: 2.
Infiniium 90000 X-Series Oscilloscopes Performance characteristics Hardware trigger (Continued) Video Triggers from negative sync composite video, field 1, field 2, or alternating fields for interlaced systems, any field, specific line, or any line for interlaced or non-interlaced systems.
Infiniium 90000 X-Series Oscilloscopes Performance characteristics Maximum measurement update rate > 50,000 measurement/sec (one measurement turned on) > 250,000 measurement/sec/measurement (ten measurements turned on) Measurement modes Standard, Measure all edges mode Waveform measurements Voltage Peak to peak, minimum, maximum, average, RMS, amplitude, base, top, overshoot, preshoot, upper, middle, lower, overshoot, V preshoot, crossing, Pulse base, pulse amplitude, burst interval Time Rise time, f
Infiniium 90000 X-Series Oscilloscopes Performance characteristics Waveform math Number of functions Sixteen Hardware accelerated math Differential and Common Mode Operations/functions Absolute value, add, average, Butterworth*, common mode, differentiate, divide, FFT magnitude, FFT phase, FIR*, high pass ilter, histogram, integrate, invert, LFE*, low pass ilter (4th-order Bessel Thompson ilter), measurement trend, magnify, max, min, multiply, RT Eye*, smoothing, SqrtSumOfSquare*, square, square root,
Infiniium 90000 X-Series Oscilloscopes Performance characteristics Computer system and peripherals Operating system Windows 7 CPU Intel® Core 2 Duo 3.06 GHz PC system memory 4GB DDR2 Drives ≥ 250-GB internal hard drive Optional removable solid state drive (Option 801) Optional USB external DVD-RW drive (Option 820) Peripherals Logitech optical USB mouse, compact USB keyboard and stylus supplied.
Agilent Technologies Oscilloscopes Multiple form factors from 20 MHz to > 90 GHz | Industry leading specs | Powerful applications 36
www.agilent.com myAgilent myAgilent www.agilent.com/find/myagilent A personalized view into the information most relevant to you. For more information on Agilent Technologies’ products, applications or services, please contact your local Agilent office. The complete list is available at: www.agilent.com/find/contactus www.lxistandard.org LAN eXtensions for Instruments puts the power of Ethernet and the Web inside your test systems. Agilent is a founding member of the LXI consortium. www.pxisa.