Technical data

Table Of Contents
Trigger Commands 33
Agilent Infiniium 9000 Series Oscilloscopes Programmer's Reference 929
:TRIGger:DELay:EDELay:SOURce
Command :TRIGger:DELay:EDELay:SOURce {CHANnel<N> | DIGital<M>}
This command sets the Event source for a Delay By Event trigger event.
<N> An integer, 1-4.
<M> An integer, 0- 15. Digital channels are available on mixed-signal
oscilloscopes.
Query
:TRIGger:DELay:EDELay:SOURce?
The query returns the currently defined Event source in the Delay By
Event trigger mode.
Returned Format
[:TRIGger:DELay:EDELay:SOURce] {CHANnel<N> | DIGital<M>}<NL>