1060 Agilent Infiniium 9000 Series Oscilloscopes Programmer's Reference
33 Trigger Commands
:TRIGger:ADVanced:VIOLation:SETup:SETup:TIME
Command :TRIGger:ADVanced:VIOLation:SETup:SETup:TIME <time>
This command specifies the amount of setup time used to test for a trigger
violation. The setup time is the amount of time that the data must be
stable and valid prior to a clock edge.
<time> Setup time, in seconds.
Query
:TRIGger:ADVanced:VIOLation:SETup:SETup:TIME?
The query returns the currently defined setup time for the trigger
violation.
Returned Format
[:TRIGger:ADVanced:VIOLation:SETup:SETup:TIME] <time><NL>