580 Agilent InfiniiVision 6000 Series Oscilloscopes Programmer's Guide
5 Commands by Subsystem
:TRIGger:M1553:PATTern:DATA
(see page 798)
Command Syntax
:TRIGger:M1553:PATTern:DATA <string>
<string> ::= "nn...n" where n ::= {0 |1|X}
The :TRIGger:M1553:PATTern:DATA command sets the 11 bits to trigger on
if the trigger type has been set to RTA11 (RTA + 11 Bits) using the
:TRIG:M1553:TYPE command.
Query Syntax
:TRIGger:M1553:PATTern:DATA?
The :TRIGger:M1553:PATTern:DATA? query returns the current 11- bit
setting.
Return Format
<string><NL>
<string> ::= "nn...n" where n ::= {0 |1|X}
See Also "Introduction to :TRIGger Commands" on page 479