Technical data

Table Of Contents
530 Agilent InfiniiVision 6000 Series Oscilloscopes Programmer's Guide
5 Commands by Subsystem
:TRIGger:GLITch:RANGe
<less_than_time>[suff
ix],
<greater_than_time>[s
uffix] (see page 536)
:TRIGger:GLITch:RANGe
? (see page 536)
<less_than_time> ::= 15 ns to
10 seconds in NR3 format
<greater_than_time> ::= 10 ns to
9.99 seconds in NR3 format
[suffix] ::= {s | ms | us | ns |
ps}
:TRIGger:GLITch:SOURc
e <source> (see
page 537)
:TRIGger:GLITch:SOURc
e? (see page 537)
<source> ::= {CHANnel<n> |
EXTernal} for DSO models
<source> ::= {CHANnel<n> |
DIGital0,..,DIGital15 } for MSO
models
<n> ::= 1-2 or 1-4 in NR1 format
Table 83 :TRIGger:GLITch Commands Summary (continued)
Command Query Options and Query Returns