Technical data

Table Of Contents
432 Agilent InfiniiVision 6000 Series Oscilloscopes Programmer's Guide
5 Commands by Subsystem
:SBUS Commands
Control oscilloscope functions associated with the serial decode bus. See
"Introduction to :SBUS Commands" on page 433.
Table 74 :SBUS Commands Summary
Command Query Options and Query Returns
n/a :SBUS:CAN:COUNt:ERRor
? (see page 434)
<frame_count> ::= integer in NR1
format
n/a :SBUS:CAN:COUNt:OVERl
oad? (see page 435)
<frame_count> ::= integer in NR1
format
:SBUS:CAN:COUNt:RESet
(see page 436)
n/a n/a
n/a :SBUS:CAN:COUNt:TOTal
? (see page 437)
<frame_count> ::= integer in NR1
format
n/a :SBUS:CAN:COUNt:UTILi
zation? (see
page 438)
<percent> ::= floating-point in
NR3 format
:SBUS:DISPlay {{0 |
OFF} | {1 | ON}} (see
page 439)
:SBUS:DISPlay? (see
page 439)
{0 | 1}
n/a :SBUS:FLEXray:COUNt:N
ULL? (see page 440)
<frame_count> ::= integer in NR1
format
:SBUS:FLEXray:COUNt:R
ESet (see page 441)
n/a n/a
n/a :SBUS:FLEXray:COUNt:S
YNC? (see page 442)
<frame_count> ::= integer in NR1
format
n/a :SBUS:FLEXray:COUNt:T
OTal? (see page 443)
<frame_count> ::= integer in NR1
format
:SBUS:I2S:BASE <base>
(see page 444)
:SBUS:I2S:BASE? (see
page 444)
<base> ::= {DECimal | HEX}
:SBUS:IIC:ASIZe
<size> (see page 445)
:SBUS:IIC:ASIZe? (see
page 445)
<size> ::= {BIT7 | BIT8}
:SBUS:LIN:PARity {{0
| OFF} | {1 | ON}}
(see page 446)
:SBUS:LIN:PARity?
(see page 446)
{0 | 1}
:SBUS:M1553:BASE
<base> (see page 447)
:SBUS:M1553:BASE?
(see page 447)
<base> ::= {DECimal | HEX}
:SBUS:MODE <mode>
(see page 448)
:SBUS:MODE? (see
page 448
)
<mode> ::= {CAN | FLEXray | I2S |
IIC | LIN | SPI | UART}