Technical data

Table Of Contents
Commands by Subsystem 5
Agilent InfiniiVision 6000 Series Oscilloscopes Programmer's Guide 251
:DIGital<n>:DISPlay
(see page 798)
Command Syntax
:DIGital<n>:DISPlay <display>
<display> ::= {{1 | ON} | {0 | OFF}}
<n> ::= An integer, 0, 1,..,15, is attached as a suffix to the command
and defines the logic channel that is affected by the command.
The :DIGital<n>:DISPlay command turns digital display on or off for the
specified channel.
Query Syntax
:DIGital<n>:DISPlay?
The :DIGital<n>:DISPlay? query returns the current digital display setting
for the specified channel.
Return Format
<display><NL>
<display> ::= {0 | 1}
See Also "Introduction to :DIGital<n> Commands" on page 249
":POD<n>:DISPlay" on page 405
":CHANnel<n>:DISPlay" on page 234
":VIEW" on page 192
":BLANk" on page 160
":STATus" on page 189
NOTE
This command is only valid for the MSO models.