:DIGital<n> Commands
Control all oscilloscope functions associated with individual digital
channels. See "Introduction to :DIGital<n> Commands" on page 249.
Introduction to
:DIGital<n>
Commands
<n> ::= {0,..,15}
The DIGital subsystem commands control the viewing, labeling, and
positioning of digital channels. They also control threshold settings for
groups of digital channels (D0- D7, D8- D15).
Reporting the Setup
Use :DIGital<n>? to query setup information for the DIGital subsystem.
Table 62 :DIGital<n> Commands Summary
Command Query Options and Query Returns
:DIGital<n>:DISPlay
{{0 | OFF} | {1 |
ON}} (see page 251)
:DIGital<n>:DISPlay?
(see page 251)
{0 | 1}
<n> ::= 0-15; an integer in NR1
format
:DIGital<n>:LABel
<string> (see
page 252)
:DIGital<n>:LABel?
(see page 252)
<string> ::= any series of 10 or
less ASCII characters enclosed in
quotation marks
<n> ::= 0-15; an integer in NR1
format
:DIGital<n>:POSition
<position> (see
page 253)
:DIGital<n>:POSition?
(see page 253)
<n> ::= 0-15; an integer in NR1
format
<position> ::= 0-7 if display
size = large, 0-15 if size =
medium, 0-31 if size = small
:DIGital<n>:SIZE
<value> (see
page 254)
:DIGital<n>:SIZE?
(see page 254)
<value> ::= {SMALl | MEDium |
LARGe}
:DIGital<n>:THReshold
<value>[suffix] (see
page 255)
:DIGital<n>:THReshold
? (see page 255)
<n> ::= 0-15; an integer in NR1
format
<value> ::= {CMOS | ECL | TTL |
<user defined value>}
<user defined value> ::= value in
NR3 format from -8.00 to +8.00
[suffix] ::= {V | mV | uV}
NOTE