Technical data

Table Of Contents
234 Agilent InfiniiVision 6000 Series Oscilloscopes Programmer's Guide
5 Commands by Subsystem
:CHANnel<n>:DISPlay
(see page 798)
Command Syntax
:CHANnel<n>:DISPlay <display value>
<display value> ::= {{1 | ON} | {0 | OFF}}
<n>::={1|2|3|4}forthefour channel oscilloscope models
<n> ::= {1 | 2} for the two channel oscilloscope models
The :CHANnel<n>:DISPlay command turns the display of the specified
channel on or off.
Query Syntax
:CHANnel<n>:DISPlay?
The :CHANnel<n>:DISPlay? query returns the current display setting for
the specified channel.
Return Format
<display value><NL>
<display value> ::= {1 | 0}
See Also "Introduction to :CHANnel<n> Commands" on page 230
":VIEW" on page 192
":BLANk" on page 160
":STATus" on page 189
":POD<n>:DISPlay" on page 405
":DIGital<n>:DISPlay" on page 251