:TRIGger:UART:BASE
(see page 750)
Command Syntax
:TRIGger:UART:BASE <base>
<base> ::= {ASCii | HEX}
The :TRIGger:UART:BASE command sets the front panel UART/RS232
trigger setup data selection option:
• ASCii — front panel data selection is from ASCII values.
• HEX — front panel data selection is from hexadecimal values.
The :TRIGger:UART:BASE setting does not affect the :TRIGger:UART:DATA
command which can always set data values using ASCII or hexadecimal
values.
Query Syntax
:TRIGger:UART:BASE?
The :TRIGger:UART:BASE? query returns the current UART base setting.
Return Format
<base><NL>
<base> ::= {ASC | HEX}
See Also • "Introduction to :TRIGger Commands" on page 440
• ":TRIGger:MODE" on page 447
• ":TRIGger:UART:DATA" on page 576
NOTE
The :TRIGger:UART:BASE command is independent of the :SBUS:UART:BASE command