Technical data
Commands by Subsystem 5
Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 401
:SBUS:DISPlay
(see page 750)
Command Syntax
:SBUS:DISPlay <display>
<display> ::= {{1 | ON} | {0 | OFF}}
The :SBUS:DISPlay command turns displaying of the serial decode bus on
or off.
Query Syntax
:SBUS:DISPlay?
The :SBUS:DISPlay? query returns the current display setting of the serial
decode bus.
Return Format
<display><NL>
<display> ::= {0 | 1}
Errors • "- 241, Hardware missing" on page 709
See Also • "Introduction to :SBUS Commands" on page 395
• ":CHANnel<n>:DISPlay" on page 208
• ":VIEW" on page 176
• ":BLANk" on page 144
• ":STATus" on page 173
NOTE
This command is only valid on 4 (analog) channel oscilloscope models when a serial decode
option has been licensed.