Technical data

274 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide
5 Commands by Subsystem
:MARKer Commands
Set and query the settings of X-axis markers (X1 and X2 cursors) and the
Y- axis markers (Y1 and Y2 cursors). See "Introduction to :MARKer
Commands" on page 275.
Table 61 :MARKer Commands Summary
Command Query Options and Query Returns
:MARKer:MODE <mode>
(see page 276)
:MARKer:MODE? (see
page 276)
<mode> ::= {OFF | MEASurement |
MANual | WAVeform}
:MARKer:X1Position
<position>[suffix]
(see page 277)
:MARKer:X1Position?
(see page 277)
<position> ::= X1 cursor position
value in NR3 format
[suffix] ::= {s | ms | us | ns |
ps | Hz | kHz | MHz}
<return_value> ::= X1 cursor
position value in NR3 format
:MARKer:X1Y1source
<source> (see
page 278)
:MARKer:X1Y1source?
(see page 278)
<source> ::= {CHANnel<n> |
FUNCtion | MATH}
<n> ::= 1-2 or 1-4 in NR1 format
<return_value> ::= <source>
:MARKer:X2Position
<position>[suffix]
(see page 279)
:MARKer:X2Position?
(see page 279)
<position> ::= X2 cursor position
value in NR3 format
[suffix] ::= {s | ms | us | ns |
ps | Hz | kHz | MHz}
<return_value> ::= X2 cursor
position value in NR3 format
:MARKer:X2Y2source
<source> (see
page 280)
:MARKer:X2Y2source?
(see page 280)
<source> ::= {CHANnel<n> |
FUNCtion | MATH}
<n> ::= 1-2 or 1-4 in NR1 format
<return_value> ::= <source>
n/a :MARKer:XDELta? (see
page 281)
<return_value> ::= X cursors
delta value in NR3 format
:MARKer:Y1Position
<position>[suffix]
(see page 282)
:MARKer:Y1Position?
(see page 282)
<position> ::= Y1 cursor position
value in NR3 format
[suffix] ::= {V | mV | dB}
<return_value> ::= Y1 cursor
position value in NR3 format