Technical data
262 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide
5 Commands by Subsystem
:HARDcopy:AREA
(see page 750)
Command Syntax
:HARDcopy:AREA <area>
<area> ::= SCReen
The :HARDcopy:AREA command controls what part of the display area is
printed. Currently, the only legal choice is SCReen.
Query Syntax
:HARDcopy:AREA?
The :HARDcopy:AREA? query returns the selected display area.
Return Format
<area><NL>
<area> ::= SCR
See Also • "Introduction to :HARDcopy Commands" on page 261
• ":HARDcopy:STARt" on page 270
• ":HARDcopy:APRinter" on page 263
• ":HARDcopy:PRINter:LIST" on page 269
• ":HARDcopy:FACTors" on page 264
• ":HARDcopy:FFEed" on page 265
• ":HARDcopy:INKSaver" on page 266
• ":HARDcopy:LAYout" on page 267
• ":HARDcopy:PALette" on page 268