Technical data
144 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide
5 Commands by Subsystem
:BLANk
(see page 750)
Command Syntax
:BLANk [<source>]
<source> ::= {CHANnel<n> | FUNCtion | MATH | SBUS}
<n>::={1|2|3|4}forthefour channel oscilloscope models
<n> ::= {1 | 2} for the two channel oscilloscope models
The :BLANk command turns off (stops displaying) the specified channel,
math function, or serial decode bus. The :BLANk command with no
parameter turns off all sources.
See Also • "Introduction to Root (:) Commands" on page 138
• ":CDISplay" on page 145
• ":CHANnel<n>:DISPlay" on page 208
• ":FUNCtion:DISPlay" on page 247
• ":SBUS:DISPlay" on page 401
• ":STATus" on page 173
• ":VIEW" on page 176
Example Code • "Example Code" on page 176
NOTE
To turn on (start displaying) a channel, etc., use the :VIEW command. The DISPlay
commands, :CHANnel<n>:DISPlay, :FUNCtion:DISPlay, or :SBUS:DISPlay are the preferred
method to turn on/off a channel, etc.
NOTE
MATH is an alias for FUNCtion.