User`s guide

Triggering 4
InfiniiVision Oscilloscopes User’s Guide 109
11 Press the Mode softkey and select Asynchronous.
12 Press the Baud and Channel softkeys and set the parameters to match your device
under test. Note that FlexRay Channel A setting on the oscilloscope is associated with
the FlexRay1 input of the VPT1000. FlexRay Channel B is associated with FlexRay2.
13 In the VPT1000 Menu, press the LAN Address softkey to access the VPT1000 LAN
Addresses Menu.
14 Enter the VPT1000’s 4-byte IP address:
a Press the Value softkey and use the Entry knob to select a byte value.
b Press the Next softkey to access the next byte.
15 When you have finished entering the IP address, press the Apply softkey.
The oscilloscope will begin showing asynchronous FlexRay decode if valid FlexRay traffic
is on the bus.
Selecting Asynchronous, Synchronous, or PC Mode
First, access the VPT1000 Menu.
1 In the Waveform section on the front panel, press the [Acquire] key.
2 Press the Serial Decode softkey, and use the Entry knob to select FlexRay.
3 Press the Decode softkey to enable decode.
4 Press the Settings softkey to access the VPT1000 Menu.
Baud (in PC or
Async modes)
Mode
Channel
Return to
previous menu
TDMA Struct
(Sync Mode)
VPT1000
LAN Address
NOTE
Changing the VPT1000 settings in the Serial Decode Menu also changes them in the
FlexRay Trigger Menu.