:TRIGger:TV:POLarity
(see page 860)
Command Syntax
:TRIGger:TV:POLarity <polarity>
<polarity> ::= {POSitive | NEGative}
The :TRIGger:TV:POLarity command sets the polarity for the TV trigger.
Query Syntax
:TRIGger:TV:POLarity?
The :TRIGger:TV:POLarity? query returns the TV trigger polarity.
Return Format
<polarity><NL>
<polarity> ::= {POS | NEG}
See Also "Introduction to :TRIGger Commands" on page 641
":TRIGger:MODE" on page 648
":TRIGger:TV:SOURce" on page 700