Technical data

Table Of Contents
:SEARch Commands 25
Agilent InfiniiVision 3000 X-Series Oscilloscopes Programmer's Guide 603
:SEARch:SERial:LIN:MODE
(see page 860)
Command Syntax
:SEARch:SERial:LIN:MODE <value>
<value> ::= {ID | DATA | ERRor}
The :SEARch:SERial:LIN:MODE command selects the type of LIN
information to find in the Lister display:
ID — searches for a frame ID.
DATA — searches for a frame ID and data.
ERRor — searches for errors.
Frame IDs are specified usind the :SEARch:SERial:LIN:ID command.
Data values are specified using the:SEARch:SERial:LIN:PATTern:DATA
command.
Query Syntax
:SEARch:SERial:LIN:MODE?
The :SEARch:SERial:LIN:MODE? query returns the currently selected mode.
Return Format
<value><NL>
<value> ::= {ID | DATA | ERR}
See Also Chapter 25, “:SEARch Commands,” starting on page 557
":SEARch:SERial:LIN:ID" on page 602
":SEARch:SERial:LIN:PATTern:DATA" on page 604