Technical data

Table Of Contents
:SBUS<n> Commands 24
Agilent InfiniiVision 3000 X-Series Oscilloscopes Programmer's Guide 477
:SBUS<n>:I2S:ALIGnment
(see page 860)
Command Syntax
:SBUS<n>:I2S:ALIGnment <setting>
<setting> ::= {I2S | LJ | RJ}
The :SBUS<n>:I2S:ALIGnment command selects the data alignment of the
I2S bus for the serial decoder and/or trigger when in I2S mode:
I2S — standard.
LJ — left justified.
RJ — right justified.
Note that the word select (WS) polarity is specified separately with the
:SBUS<n>:I2S:WSLow command.
Query Syntax
:SBUS<n>:I2S:ALIGnment?
The :SBUS<n>:I2S:ALIGnment? query returns the currently selected I2S
data alignment.
Return Format
<setting><NL>
<setting> ::= {I2S | LJ | RJ}
See Also "Introduction to :TRIGger Commands" on page 641
":SBUS<n>:I2S:CLOCk:SLOPe" on page 479
":SBUS<n>:I2S:RWIDth" on page 480
":SBUS<n>:I2S:TWIDth" on page 492
":SBUS<n>:I2S:WSLow" on page 493