Technical data

Table Of Contents
458 Agilent InfiniiVision 3000 X-Series Oscilloscopes Programmer's Guide
24 :SBUS<n> Commands
:SBUS<n>:CAN Commands
NOTE
These commands are valid on when the automotive CAN and LIN serial decode option
(Option AMS) has been licensed.
Table 85 :SBUS<n>:CAN Commands Summary
Command Query Options and Query Returns
n/a :SBUS<n>:CAN:COUNt:ER
Ror? (see page 460)
<frame_count> ::= integer in NR1
format
n/a :SBUS<n>:CAN:COUNt:OV
ERload? (see
page 461)
<frame_count> ::= integer in NR1
format
:SBUS<n>:CAN:COUNt:RE
Set (see page 462)
n/a n/a
n/a :SBUS<n>:CAN:COUNt:TO
Tal? (see page 463)
<frame_count> ::= integer in NR1
format
n/a :SBUS<n>:CAN:COUNt:UT
ILization? (see
page 464)
<percent> ::= floating-point in
NR3 format
:SBUS<n>:CAN:SAMPlepo
int <value> (see
page 465)
:SBUS<n>:CAN:SAMPlepo
int? (see page 465)
<value> ::= {60 | 62.5 | 68 | 70
| 75 | 80 | 87.5} in NR3 format
:SBUS<n>:CAN:SIGNal:B
AUDrate <baudrate>
(see page 466)
:SBUS<n>:CAN:SIGNal:B
AUDrate? (see
page 466)
<baudrate> ::= integer from 10000
to 1000000 in 100 b/s increments
:SBUS<n>:CAN:SIGNal:D
EFinition <value>
(see page 467)
:SBUS<n>:CAN:SIGNal:D
EFinition? (see
page 467)
<value> ::= {CANH | CANL | RX |
TX | DIFFerential | DIFL | DIFH}
:SBUS<n>:CAN:SOURce
<source> (see
page 468)
:SBUS<n>:CAN:SOURce?
(see page 468)
<source> ::= {CHANnel<n> |
EXTernal} for DSO models
<source> ::= {CHANnel<n> |
DIGital<d> |} for MSO models
<n> ::= 1 to (# analog channels)
in NR1 format
<d> ::= 0 to (# digital channels
- 1) in NR1 format
:SBUS<n>:CAN:TRIGger
<condition> (see
page 469)
:SBUS<n>:CAN:TRIGger?
(see page 470)
<condition> ::= {SOF | DATA |
ERRor | IDData | IDEither |
IDRemote | ALLerrors | OVERload |
ACKerror}