Technical data
Table Of Contents
- In This Book
- Contents
- What's New
- Setting Up
- Getting Started
- Basic Oscilloscope Program Structure
- Programming the Oscilloscope
- Referencing the IO Library
- Opening the Oscilloscope Connection via the IO Library
- Initializing the Interface and the Oscilloscope
- Using :AUToscale to Automate Oscilloscope Setup
- Using Other Oscilloscope Setup Commands
- Capturing Data with the :DIGitize Command
- Reading Query Responses from the Oscilloscope
- Reading Query Results into String Variables
- Reading Query Results into Numeric Variables
- Reading Definite-Length Block Query Response Data
- Sending Multiple Queries and Reading Results
- Checking Instrument Status
- Other Ways of Sending Commands
- Commands Quick Reference
- Common (*) Commands
- *CLS (Clear Status)
- *ESE (Standard Event Status Enable)
- *ESR (Standard Event Status Register)
- *IDN (Identification Number)
- *LRN (Learn Device Setup)
- *OPC (Operation Complete)
- *OPT (Option Identification)
- *RCL (Recall)
- *RST (Reset)
- *SAV (Save)
- *SRE (Service Request Enable)
- *STB (Read Status Byte)
- *TRG (Trigger)
- *TST (Self Test)
- *WAI (Wait To Continue)
- Root (:) Commands
- :ACTivity
- :AER (Arm Event Register)
- :AUToscale
- :AUToscale:AMODE
- :AUToscale:CHANnels
- :AUToscale:FDEBug
- :BLANk
- :DIGitize
- :MTEenable (Mask Test Event Enable Register)
- :MTERegister[:EVENt] (Mask Test Event Event Register)
- :OPEE (Operation Status Enable Register)
- :OPERegister:CONDition (Operation Status Condition Register)
- :OPERegister[:EVENt] (Operation Status Event Register)
- :OVLenable (Overload Event Enable Register)
- :OVLRegister (Overload Event Register)
- :RUN
- :SERial
- :SINGle
- :STATus
- :STOP
- :TER (Trigger Event Register)
- :VIEW
- :ACQuire Commands
- :BUS
Commands - :CALibrate Commands
- :CHANnel
Commands - :DEMO Commands
- :DIGital
Commands - :DISPlay Commands
- :EXTernal Trigger Commands
- :FUNCtion Commands
- :HARDcopy Commands
- :LISTer Commands
- :MARKer Commands
- :MEASure Commands
- :MEASure:ALL
- :MEASure:AREa
- :MEASure:BWIDth
- :MEASure:CLEar
- :MEASure:COUNter
- :MEASure:DEFine
- :MEASure:DELay
- :MEASure:DUTYcycle
- :MEASure:FALLtime
- :MEASure:FREQuency
- :MEASure:NEDGes
- :MEASure:NPULses
- :MEASure:NWIDth
- :MEASure:OVERshoot
- :MEASure:PEDGes
- :MEASure:PERiod
- :MEASure:PHASe
- :MEASure:PPULses
- :MEASure:PREShoot
- :MEASure:PWIDth
- :MEASure:RESults
- :MEASure:RISetime
- :MEASure:SDEViation
- :MEASure:SHOW
- :MEASure:SOURce
- :MEASure:STATistics
- :MEASure:STATistics:INCRement
- :MEASure:STATistics:RESet
- :MEASure:TEDGe
- :MEASure:TVALue
- :MEASure:VAMPlitude
- :MEASure:VAVerage
- :MEASure:VBASe
- :MEASure:VMAX
- :MEASure:VMIN
- :MEASure:VPP
- :MEASure:VRATio
- :MEASure:VRMS
- :MEASure:VTIMe
- :MEASure:VTOP
- :MEASure:WINDow
- :MEASure:XMAX
- :MEASure:XMIN
- :MTESt Commands
- :MTESt:ALL
- :MTESt:AMASk:CREate
- :MTESt:AMASk:SOURce
- :MTESt:AMASk:UNITs
- :MTESt:AMASk:XDELta
- :MTESt:AMASk:YDELta
- :MTESt:COUNt:FWAVeforms
- :MTESt:COUNt:RESet
- :MTESt:COUNt:TIME
- :MTESt:COUNt:WAVeforms
- :MTESt:DATA
- :MTESt:DELete
- :MTESt:ENABle
- :MTESt:LOCK
- :MTESt:RMODe
- :MTESt:RMODe:FACTion:MEASure
- :MTESt:RMODe:FACTion:PRINt
- :MTESt:RMODe:FACTion:SAVE
- :MTESt:RMODe:FACTion:STOP
- :MTESt:RMODe:SIGMa
- :MTESt:RMODe:TIME
- :MTESt:RMODe:WAVeforms
- :MTESt:SCALe:BIND
- :MTESt:SCALe:X1
- :MTESt:SCALe:XDELta
- :MTESt:SCALe:Y1
- :MTESt:SCALe:Y2
- :MTESt:SOURce
- :MTESt:TITLe
- :POD Commands
- :RECall Commands
- :SAVE Commands
- :SAVE:FILename
- :SAVE:IMAGe[:STARt]
- :SAVE:IMAGe:FACTors
- :SAVE:IMAGe:FORMat
- :SAVE:IMAGe:INKSaver
- :SAVE:IMAGe:PALette
- :SAVE:LISTer[:STARt]
- :SAVE:MASK[:STARt]
- :SAVE:PWD
- :SAVE:SETup[:STARt]
- :SAVE:WAVeform[:STARt]
- :SAVE:WAVeform:FORMat
- :SAVE:WAVeform:LENGth
- :SAVE:WAVeform:SEGMented
- :SAVE:WMEMory:SOURce
- :SAVE:WMEMory[:STARt]
- :SBUS
Commands - General :SBUS
Commands - :SBUS
:CAN Commands - :SBUS
:CAN:COUNt:ERRor - :SBUS
:CAN:COUNt:OVERload - :SBUS
:CAN:COUNt:RESet - :SBUS
:CAN:COUNt:TOTal - :SBUS
:CAN:COUNt:UTILization - :SBUS
:CAN:SAMPlepoint - :SBUS
:CAN:SIGNal:BAUDrate - :SBUS
:CAN:SIGNal:DEFinition - :SBUS
:CAN:SOURce - :SBUS
:CAN:TRIGger - :SBUS
:CAN:TRIGger:PATTern:DATA - :SBUS
:CAN:TRIGger:PATTern:DATA:LENGth - :SBUS
:CAN:TRIGger:PATTern:ID - :SBUS
:CAN:TRIGger:PATTern:ID:MODE
- :SBUS
- :SBUS
:I2S Commands - :SBUS
:IIC Commands - :SBUS
:LIN Commands - :SBUS
:SPI Commands - :SBUS
:SPI:BITorder - :SBUS
:SPI:CLOCk:SLOPe - :SBUS
:SPI:CLOCk:TIMeout - :SBUS
:SPI:FRAMing - :SBUS
:SPI:SOURce:CLOCk - :SBUS
:SPI:SOURce:DATA - :SBUS
:SPI:SOURce:FRAMe - :SBUS
:SPI:SOURce:MISO - :SBUS
:SPI:SOURce:MOSI - :SBUS
:SPI:TRIGger:PATTern:MISO:DATA - :SBUS
:SPI:TRIGger:PATTern:MISO:WIDTh - :SBUS
:SPI:TRIGger:PATTern:MOSI:DATA - :SBUS
:SPI:TRIGger:PATTern:MOSI:WIDTh - :SBUS
:SPI:TRIGger:TYPE - :SBUS
:SPI:WIDTh
- :SBUS
- :SBUS
:UART Commands - :SBUS
:UART:BASE - :SBUS
:UART:BAUDrate - :SBUS
:UART:BITorder - :SBUS
:UART:COUNt:ERRor - :SBUS
:UART:COUNt:RESet - :SBUS
:UART:COUNt:RXFRames - :SBUS
:UART:COUNt:TXFRames - :SBUS
:UART:FRAMing - :SBUS
:UART:PARity - :SBUS
:UART:POLarity - :SBUS
:UART:SOURce:RX - :SBUS
:UART:SOURce:TX - :SBUS
:UART:TRIGger:BASE - :SBUS
:UART:TRIGger:BURSt - :SBUS
:UART:TRIGger:DATA - :SBUS
:UART:TRIGger:IDLE - :SBUS
:UART:TRIGger:QUALifier - :SBUS
:UART:TRIGger:TYPE - :SBUS
:UART:WIDTh
- :SBUS
- General :SBUS
- :SEARch Commands
- :SYSTem Commands
- :TIMebase Commands
- :TRIGger Commands
- :WAVeform Commands
- :WAVeform:BYTeorder
- :WAVeform:COUNt
- :WAVeform:DATA
- :WAVeform:FORMat
- :WAVeform:POINts
- :WAVeform:POINts:MODE
- :WAVeform:PREamble
- :WAVeform:SEGMented:COUNt
- :WAVeform:SEGMented:TTAG
- :WAVeform:SOURce
- :WAVeform:SOURce:SUBSource
- :WAVeform:TYPE
- :WAVeform:UNSigned
- :WAVeform:VIEW
- :WAVeform:XINCrement
- :WAVeform:XORigin
- :WAVeform:XREFerence
- :WAVeform:YINCrement
- :WAVeform:YORigin
- :WAVeform:YREFerence
- :WGEN Commands
- :WMEMory
Commands - Obsolete and Discontinued Commands
- :CHANnel:ACTivity
- :CHANnel:LABel
- :CHANnel:THReshold
- :CHANnel2:SKEW
- :CHANnel
:INPut - :CHANnel
:PMODe - :DISPlay:CONNect
- :DISPlay:ORDer
- :ERASe
- :EXTernal:PMODe
- :FUNCtion:SOURce
- :FUNCtion:VIEW
- :HARDcopy:DESTination
- :HARDcopy:FILename
- :HARDcopy:GRAYscale
- :HARDcopy:IGColors
- :HARDcopy:PDRiver
- :MEASure:LOWer
- :MEASure:SCRatch
- :MEASure:TDELta
- :MEASure:THResholds
- :MEASure:TMAX
- :MEASure:TMIN
- :MEASure:TSTArt
- :MEASure:TSTOp
- :MEASure:TVOLt
- :MEASure:UPPer
- :MEASure:VDELta
- :MEASure:VSTArt
- :MEASure:VSTOp
- :MTESt:AMASk:{SAVE | STORe}
- :MTESt:AVERage
- :MTESt:AVERage:COUNt
- :MTESt:LOAD
- :MTESt:RUMode
- :MTESt:RUMode:SOFailure
- :MTESt:{STARt | STOP}
- :MTESt:TRIGger:SOURce
- :PRINt?
- :SAVE:IMAGe:AREA
- :SBUS
:LIN:SIGNal:DEFinition - :TIMebase:DELay
- :TRIGger:THReshold
- :TRIGger:TV:TVMode
- Error Messages
- Status Reporting
- Status Reporting Data Structures
- Status Byte Register (STB)
- Service Request Enable Register (SRE)
- Trigger Event Register (TER)
- Output Queue
- Message Queue
- (Standard) Event Status Register (ESR)
- (Standard) Event Status Enable Register (ESE)
- Error Queue
- Operation Status Event Register (:OPERegister[:EVENt])
- Operation Status Condition Register (:OPERegister:CONDition)
- Arm Event Register (AER)
- Overload Event Register (:OVLRegister)
- Mask Test Event Event Register (:MTERegister[:EVENt])
- Clearing Registers and Queues
- Status Reporting Decision Chart
- Synchronizing Acquisitions
- More About Oscilloscope Commands
- Programming Examples
- Index

:CHANnel<n> Commands 10
Agilent InfiniiVision 3000 X-Series Oscilloscopes Programmer's Guide 231
:CHANnel<n>:PROBe
(see page 860)
Command Syntax
:CHANnel<n>:PROBe <attenuation>
<attenuation> ::= probe attenuation ratio in NR3 format
<n> ::= 1 to (# analog channels) in NR1 format
The obsolete attenuation values X1, X10, X20, X100 are also supported.
The :CHANnel<n>:PROBe command specifies the probe attenuation factor
for the selected channel. The probe attenuation factor may be 0.1 to 1000.
This command does not change the actual input sensitivity of the
oscilloscope. It changes the reference constants for scaling the display
factors, for making automatic measurements, and for setting trigger levels.
If an AutoProbe probe is connected to the oscilloscope, the attenuation
value cannot be changed from the sensed value. Attempting to set the
oscilloscope to an attenuation value other than the sensed value produces
an error.
Query Syntax
:CHANnel<n>:PROBe?
The :CHANnel<n>:PROBe? query returns the current probe attenuation
factor for the selected channel.
Return Format
<attenuation><NL>
<attenuation> ::= probe attenuation ratio in NR3 format
See Also • "Introduction to :CHANnel<n> Commands" on page 222
• ":CHANnel<n>:RANGe" on page 237
• ":CHANnel<n>:SCALe" on page 238
• ":CHANnel<n>:OFFSet" on page 230
Example Code
' CHANNEL_PROBE - Sets the probe attenuation factor for the selected
' channel. The probe attenuation factor may be set from 0.1 to 1000.
myScope.WriteString ":CHANnel1:PROBe 10" ' Set Probe to 10:1.
See complete example programs at: Chapter 37, “Programming Examples,”
starting on page 869