Technical data
Table Of Contents
- In This Book
- Contents
- What's New
- Setting Up
- Getting Started
- Basic Oscilloscope Program Structure
- Programming the Oscilloscope
- Referencing the IO Library
- Opening the Oscilloscope Connection via the IO Library
- Initializing the Interface and the Oscilloscope
- Using :AUToscale to Automate Oscilloscope Setup
- Using Other Oscilloscope Setup Commands
- Capturing Data with the :DIGitize Command
- Reading Query Responses from the Oscilloscope
- Reading Query Results into String Variables
- Reading Query Results into Numeric Variables
- Reading Definite-Length Block Query Response Data
- Sending Multiple Queries and Reading Results
- Checking Instrument Status
- Other Ways of Sending Commands
- Commands Quick Reference
- Common (*) Commands
- *CLS (Clear Status)
- *ESE (Standard Event Status Enable)
- *ESR (Standard Event Status Register)
- *IDN (Identification Number)
- *LRN (Learn Device Setup)
- *OPC (Operation Complete)
- *OPT (Option Identification)
- *RCL (Recall)
- *RST (Reset)
- *SAV (Save)
- *SRE (Service Request Enable)
- *STB (Read Status Byte)
- *TRG (Trigger)
- *TST (Self Test)
- *WAI (Wait To Continue)
- Root (:) Commands
- :ACTivity
- :AER (Arm Event Register)
- :AUToscale
- :AUToscale:AMODE
- :AUToscale:CHANnels
- :AUToscale:FDEBug
- :BLANk
- :DIGitize
- :MTEenable (Mask Test Event Enable Register)
- :MTERegister[:EVENt] (Mask Test Event Event Register)
- :OPEE (Operation Status Enable Register)
- :OPERegister:CONDition (Operation Status Condition Register)
- :OPERegister[:EVENt] (Operation Status Event Register)
- :OVLenable (Overload Event Enable Register)
- :OVLRegister (Overload Event Register)
- :RUN
- :SERial
- :SINGle
- :STATus
- :STOP
- :TER (Trigger Event Register)
- :VIEW
- :ACQuire Commands
- :BUS
Commands - :CALibrate Commands
- :CHANnel
Commands - :DEMO Commands
- :DIGital
Commands - :DISPlay Commands
- :EXTernal Trigger Commands
- :FUNCtion Commands
- :HARDcopy Commands
- :LISTer Commands
- :MARKer Commands
- :MEASure Commands
- :MEASure:ALL
- :MEASure:AREa
- :MEASure:BWIDth
- :MEASure:CLEar
- :MEASure:COUNter
- :MEASure:DEFine
- :MEASure:DELay
- :MEASure:DUTYcycle
- :MEASure:FALLtime
- :MEASure:FREQuency
- :MEASure:NEDGes
- :MEASure:NPULses
- :MEASure:NWIDth
- :MEASure:OVERshoot
- :MEASure:PEDGes
- :MEASure:PERiod
- :MEASure:PHASe
- :MEASure:PPULses
- :MEASure:PREShoot
- :MEASure:PWIDth
- :MEASure:RESults
- :MEASure:RISetime
- :MEASure:SDEViation
- :MEASure:SHOW
- :MEASure:SOURce
- :MEASure:STATistics
- :MEASure:STATistics:INCRement
- :MEASure:STATistics:RESet
- :MEASure:TEDGe
- :MEASure:TVALue
- :MEASure:VAMPlitude
- :MEASure:VAVerage
- :MEASure:VBASe
- :MEASure:VMAX
- :MEASure:VMIN
- :MEASure:VPP
- :MEASure:VRATio
- :MEASure:VRMS
- :MEASure:VTIMe
- :MEASure:VTOP
- :MEASure:WINDow
- :MEASure:XMAX
- :MEASure:XMIN
- :MTESt Commands
- :MTESt:ALL
- :MTESt:AMASk:CREate
- :MTESt:AMASk:SOURce
- :MTESt:AMASk:UNITs
- :MTESt:AMASk:XDELta
- :MTESt:AMASk:YDELta
- :MTESt:COUNt:FWAVeforms
- :MTESt:COUNt:RESet
- :MTESt:COUNt:TIME
- :MTESt:COUNt:WAVeforms
- :MTESt:DATA
- :MTESt:DELete
- :MTESt:ENABle
- :MTESt:LOCK
- :MTESt:RMODe
- :MTESt:RMODe:FACTion:MEASure
- :MTESt:RMODe:FACTion:PRINt
- :MTESt:RMODe:FACTion:SAVE
- :MTESt:RMODe:FACTion:STOP
- :MTESt:RMODe:SIGMa
- :MTESt:RMODe:TIME
- :MTESt:RMODe:WAVeforms
- :MTESt:SCALe:BIND
- :MTESt:SCALe:X1
- :MTESt:SCALe:XDELta
- :MTESt:SCALe:Y1
- :MTESt:SCALe:Y2
- :MTESt:SOURce
- :MTESt:TITLe
- :POD Commands
- :RECall Commands
- :SAVE Commands
- :SAVE:FILename
- :SAVE:IMAGe[:STARt]
- :SAVE:IMAGe:FACTors
- :SAVE:IMAGe:FORMat
- :SAVE:IMAGe:INKSaver
- :SAVE:IMAGe:PALette
- :SAVE:LISTer[:STARt]
- :SAVE:MASK[:STARt]
- :SAVE:PWD
- :SAVE:SETup[:STARt]
- :SAVE:WAVeform[:STARt]
- :SAVE:WAVeform:FORMat
- :SAVE:WAVeform:LENGth
- :SAVE:WAVeform:SEGMented
- :SAVE:WMEMory:SOURce
- :SAVE:WMEMory[:STARt]
- :SBUS
Commands - General :SBUS
Commands - :SBUS
:CAN Commands - :SBUS
:CAN:COUNt:ERRor - :SBUS
:CAN:COUNt:OVERload - :SBUS
:CAN:COUNt:RESet - :SBUS
:CAN:COUNt:TOTal - :SBUS
:CAN:COUNt:UTILization - :SBUS
:CAN:SAMPlepoint - :SBUS
:CAN:SIGNal:BAUDrate - :SBUS
:CAN:SIGNal:DEFinition - :SBUS
:CAN:SOURce - :SBUS
:CAN:TRIGger - :SBUS
:CAN:TRIGger:PATTern:DATA - :SBUS
:CAN:TRIGger:PATTern:DATA:LENGth - :SBUS
:CAN:TRIGger:PATTern:ID - :SBUS
:CAN:TRIGger:PATTern:ID:MODE
- :SBUS
- :SBUS
:I2S Commands - :SBUS
:IIC Commands - :SBUS
:LIN Commands - :SBUS
:SPI Commands - :SBUS
:SPI:BITorder - :SBUS
:SPI:CLOCk:SLOPe - :SBUS
:SPI:CLOCk:TIMeout - :SBUS
:SPI:FRAMing - :SBUS
:SPI:SOURce:CLOCk - :SBUS
:SPI:SOURce:DATA - :SBUS
:SPI:SOURce:FRAMe - :SBUS
:SPI:SOURce:MISO - :SBUS
:SPI:SOURce:MOSI - :SBUS
:SPI:TRIGger:PATTern:MISO:DATA - :SBUS
:SPI:TRIGger:PATTern:MISO:WIDTh - :SBUS
:SPI:TRIGger:PATTern:MOSI:DATA - :SBUS
:SPI:TRIGger:PATTern:MOSI:WIDTh - :SBUS
:SPI:TRIGger:TYPE - :SBUS
:SPI:WIDTh
- :SBUS
- :SBUS
:UART Commands - :SBUS
:UART:BASE - :SBUS
:UART:BAUDrate - :SBUS
:UART:BITorder - :SBUS
:UART:COUNt:ERRor - :SBUS
:UART:COUNt:RESet - :SBUS
:UART:COUNt:RXFRames - :SBUS
:UART:COUNt:TXFRames - :SBUS
:UART:FRAMing - :SBUS
:UART:PARity - :SBUS
:UART:POLarity - :SBUS
:UART:SOURce:RX - :SBUS
:UART:SOURce:TX - :SBUS
:UART:TRIGger:BASE - :SBUS
:UART:TRIGger:BURSt - :SBUS
:UART:TRIGger:DATA - :SBUS
:UART:TRIGger:IDLE - :SBUS
:UART:TRIGger:QUALifier - :SBUS
:UART:TRIGger:TYPE - :SBUS
:UART:WIDTh
- :SBUS
- General :SBUS
- :SEARch Commands
- :SYSTem Commands
- :TIMebase Commands
- :TRIGger Commands
- :WAVeform Commands
- :WAVeform:BYTeorder
- :WAVeform:COUNt
- :WAVeform:DATA
- :WAVeform:FORMat
- :WAVeform:POINts
- :WAVeform:POINts:MODE
- :WAVeform:PREamble
- :WAVeform:SEGMented:COUNt
- :WAVeform:SEGMented:TTAG
- :WAVeform:SOURce
- :WAVeform:SOURce:SUBSource
- :WAVeform:TYPE
- :WAVeform:UNSigned
- :WAVeform:VIEW
- :WAVeform:XINCrement
- :WAVeform:XORigin
- :WAVeform:XREFerence
- :WAVeform:YINCrement
- :WAVeform:YORigin
- :WAVeform:YREFerence
- :WGEN Commands
- :WMEMory
Commands - Obsolete and Discontinued Commands
- :CHANnel:ACTivity
- :CHANnel:LABel
- :CHANnel:THReshold
- :CHANnel2:SKEW
- :CHANnel
:INPut - :CHANnel
:PMODe - :DISPlay:CONNect
- :DISPlay:ORDer
- :ERASe
- :EXTernal:PMODe
- :FUNCtion:SOURce
- :FUNCtion:VIEW
- :HARDcopy:DESTination
- :HARDcopy:FILename
- :HARDcopy:GRAYscale
- :HARDcopy:IGColors
- :HARDcopy:PDRiver
- :MEASure:LOWer
- :MEASure:SCRatch
- :MEASure:TDELta
- :MEASure:THResholds
- :MEASure:TMAX
- :MEASure:TMIN
- :MEASure:TSTArt
- :MEASure:TSTOp
- :MEASure:TVOLt
- :MEASure:UPPer
- :MEASure:VDELta
- :MEASure:VSTArt
- :MEASure:VSTOp
- :MTESt:AMASk:{SAVE | STORe}
- :MTESt:AVERage
- :MTESt:AVERage:COUNt
- :MTESt:LOAD
- :MTESt:RUMode
- :MTESt:RUMode:SOFailure
- :MTESt:{STARt | STOP}
- :MTESt:TRIGger:SOURce
- :PRINt?
- :SAVE:IMAGe:AREA
- :SBUS
:LIN:SIGNal:DEFinition - :TIMebase:DELay
- :TRIGger:THReshold
- :TRIGger:TV:TVMode
- Error Messages
- Status Reporting
- Status Reporting Data Structures
- Status Byte Register (STB)
- Service Request Enable Register (SRE)
- Trigger Event Register (TER)
- Output Queue
- Message Queue
- (Standard) Event Status Register (ESR)
- (Standard) Event Status Enable Register (ESE)
- Error Queue
- Operation Status Event Register (:OPERegister[:EVENt])
- Operation Status Condition Register (:OPERegister:CONDition)
- Arm Event Register (AER)
- Overload Event Register (:OVLRegister)
- Mask Test Event Event Register (:MTERegister[:EVENt])
- Clearing Registers and Queues
- Status Reporting Decision Chart
- Synchronizing Acquisitions
- More About Oscilloscope Commands
- Programming Examples
- Index

:ACQuire Commands 7
Agilent InfiniiVision 3000 X-Series Oscilloscopes Programmer's Guide 189
:ACQuire:COMPlete
(see page 860)
Command Syntax
:ACQuire:COMPlete <complete>
<complete> ::= 100; an integer in NR1 format
The :ACQuire:COMPlete command affects the operation of the :DIGitize
command. It specifies the minimum completion criteria for an acquisition.
The parameter determines the percentage of the time buckets that must be
"full" before an acquisition is considered complete. If :ACQuire:TYPE is
NORMal, it needs only one sample per time bucket for that time bucket to
be considered full.
The only legal value for the :COMPlete command is 100. All time buckets
must contain data for the acquisition to be considered complete.
Query Syntax
:ACQuire:COMPlete?
The :ACQuire:COMPlete? query returns the completion criteria (100) for
the currently selected mode.
Return Format
<completion_criteria><NL>
<completion_criteria> ::= 100; an integer in NR1 format
See Also • "Introduction to :ACQuire Commands" on page 187
• ":ACQuire:TYPE" on page 199
• ":DIGitize" on page 163
• ":WAVeform:POINts" on page 720
Example Code
' AQUIRE_COMPLETE - Specifies the minimum completion criteria for
' an acquisition. The parameter determines the percentage of time
' buckets needed to be "full" before an acquisition is considered
' to be complete.
myScope.WriteString ":ACQuire:COMPlete 100"
See complete example programs at: Chapter 37, “Programming Examples,”
starting on page 869