Specifications

4-14
Operating Features and Specifications
Data Input
Data Input
The error detector data input port offers the following features, selectable using the
key and its menu of softkeys.
Features
Data polarity - normal or inverted data.
Auto or manual slicing.
Set manual slicing level.
Termination voltage - 0/2V.
Measure auto slicing voltage.
Clock/Data delay adjust.
Clock/Data alignment.
0/1 threshold centre.
Specifications
Impedance: 50to 0V or 2V, dc coupled.
Format: NRZ.
Amplitude: 0.5 to 1 V pp.
Sensitivity: <50 mV pp (typical for 2 ^231 PRBS input at 10 Gb/s 0V high level).
<100 mV pp (typical for 2 ^231 PRBS input at 12.5 Gb/s 0V high level).
Decision threshold range: +1V to 3V in 1 mV steps.
Range: +1.5V to 4V.
Data input range: +1.5V to 4V.
Clock/Data phase alignment: ±1nsin1pssteps(100MHzto3GHz)
1 clock period (3 to 12.5 GHz) in 1 ps steps.
Connector: APC-3.5 mm male connector.
Pattern Trigger Output (error detector)
Provide an electrical trigger synchronous with the error detector reference pattern.
input & eye