Pattern Generator DATA OUT
Pattern Generator DATA OUT
In this section the SOURCE1:VOLT and OUTPUT1 commands control the electrical
levels at the DATA OUT port. Refer to the next section on page 5-17 for
SOURCE10:VOLT and OUTPUT10 commands which provide the corresponding
controls, where independently available, for the DATA OUT port.
NOTE See Handling Coupled Parameters,page2-11.
[SOURce[1]:]VOLTage[:LEVel][:IMMediate][:AMPLitude] <numeric
value>
Sets the peak to peak value of the data signal, in units of Volts.
The *RST selection is 500 mV.
[SOURce[1]:]VOLTage[:LEVeI][:IMMediate]:HIGH <numeric value>
This is used to set the dc high output level, in units of Volts.
The *RST selection is 0 V.
[SOURce[1]:]VOLTage:ATTenuation <numeric value>
Specifies, in decibels, the value of external attenuation on the output. This causes the
entered/displayed values to be modified so as to reflect the value of the output on the far
side of the attenuator.
The *RST selection is 0 dB.
[SOURce[1]:]VOLTage:ECL
Sets the output AMPLitude and HIGH values to those used for the ECL family. There is
no query form of this command.
OUTPut1[:STATe] <boolean>
This node controls the data output. When OFF, the output is set to 0 V.