Specifications
12-6
Error Messages
Non-Permanent Errors
430 Disk check read error Check read error. An error was detected when reading
the data just written. The media is probably damaged.
431 Corrupt disk Disk may be corrupt.
435 Unable to reload edit buffer During power-on, the user pattern memory could not
be reloaded from the appropriate pattern store (the disk
last used for the UPAT selection was not inserted at
power-on).
439 Not allowed in manual gating The action requested is not allowed while manual
gating mode is selected.
440 Allowed only in repetitive gating The action requested is allowed only while repetitive
gating mode is selected.
441 Allowed only for HEX entry The action requested is allowed only while HEX data
entryisselected.
442 Allowed only when user’s page
selected
The action requested is allowed only while the User’s
Page is selected.
443 Allowed only when tracking
disabled
The action requested is allowed only while the output
tracking is disabled.
444 No pattern generator present The action requested is not allowed because there is
no pattern generator module
445 No error detector present The action requested is not allowed because there is
no error detector module.
446 Not allowed in divided clock
mode
The action requested is not allowed when the trigger
mode is set to divided clock.
447 Allowed only in divided clock
mode
The action requested is allowed only when the trigger
mode is set to divided clock.
448 Allowed only for pure PRBS
patterns
The action requested is allowed only when the pattern
is a pure, non-modified PRBS.
449 Not allowed for pure PRBS
patterns
Theactionrequestedisnotallowedwhenthepatternis
a pure, non-modified PRBS
450 Allowed only in block BER mode The action requested is allowed only when the error
location Block BER mode is selected.
451 Not allowed in block BER mode The action requested is not allowed when the error
location Block BER mode is selected.
452 Not allowed in burst gating mode The action requested is not allowed when the burst
gating mode is selected.
453 Allowed only for zero sub
patterns
The action requested is allowed only when there is a
zero sub pattern selected.
Non-Permanent Errors, continued
Error No. Displayed Message Description