Specifications

12-3
Error Messages
Non-Permanent Errors
Non-Permanent Errors
Non-Permanent Errors
Error No. Displayed Message Description
101 Invalid set option An invalid set option was detected on an GP-IB set
command.
102 Invalid query option An invalid query option was detected on an GP-IB
query command.
103 Already gating The instrument cannot be commanded to start gating
while it is already gating.
104 Already not gating The instrument cannot be commanded to end gating
while it is already not gating.
105 Not while gating This command is not permitted while the instrument is
gating.
106 Clock attenuator too large Attempt to specify a value of “Ext Atten” for the CLOCK
and CLOCK OUT/ which is out of range.
107 Keyboard locked Commands that change the instrument’s configuration
are not permitted while the keyboard is locked.
109 Pattern length too short for Block
BER
Block BER cannot be selected if the current pattern
length is less than 32.
110 Window too small The size of the window allocated on the Agilent
70004A Display is inadequate; a full size window is
needed.
111 Conflicts with run of zeros The zero-substitution pattern requested is incompatible
with the current setting of the run of zeros.
112 Conflicts with zsub length The run of zeros requested is incompatible with the
current setting of the zero-substitution length.
113 Conflicts with data high level The data amplitude requested is incompatible with the
current setting of the data high level.
114 Conflicts with data amplitude The data high level requested is incompatible with the
current setting of the data amplitude.
115 Not enough room on User’s
Page
The item cannot be added to the User’s Page because
there is insufficient space remaining.
116 Clock freq exceeds maximum of
option
The requested frequency setting is higher than the
maximum for this instrument option.