User`s guide

Appendix D 653
Softkey Functions
Analysis Menu
D. Softkey Functions
(Continued)
Fixture Simulator
Topology
*1
Port2 (bal)
4-1
*2
Selects test ports 4 and 1 on the analyzer for connection with (balanced)
port 2 on the DUT (ports b and c for
SE-Bal or ports c and d for Bal-Bal in
Table 7-8 on page 296) respectively.
:CALC{1-16}:FSIM:BAL:TOP:BBAL
:CALC{1-16}:FSIM:BAL:TOP:SBAL
4-2
*2
Selects test ports 4 and 2 on the analyzer for connection with (balanced)
port 2 on the DUT (ports b and c for
SE-Bal or ports c and d for Bal-Bal in
Table 7-8 on page 296) respectively.
:CALC{1-16}:FSIM:BAL:TOP:BBAL
:CALC{1-16}:FSIM:BAL:TOP:SBAL
4-3
*2
Selects test ports 4 and 3 on the analyzer for connection with (balanced)
port 2 on the DUT (ports b and c for
SE-Bal or ports c and d for Bal-Bal in
Table 7-8 on page 296) respectively.
:CALC{1-16}:FSIM:BAL:TOP:BBAL
:CALC{1-16}:FSIM:BAL:TOP:SBAL
Cancel
Returns to the softkey display screen one level higher.
Port2 (se)
*2
Displays softkeys for selecting the analyzer port (test port) to which (single-end) port 2 on the DUT will be
connected. This key will be displayed only when
SE-SE-Bal in the Device menu is selected.
1 Selects test port 1 on the analyzer for connection with (single-end) port 2 on
the DUT.
:CALC{1-16}:FSIM:BAL:TOP:SSB
2
Selects test port 2 on the analyzer for connection with (single-end) port 2 on
the DUT.
:CALC{1-16}:FSIM:BAL:TOP:SSB
3
Selects test port 3 on the analyzer for connection with (single-end) port 2 on
the DUT.
:CALC{1-16}:FSIM:BAL:TOP:SSB
4
Selects test port 4 on the analyzer for connection with (single-end) port 2 on
the DUT.
:CALC{1-16}:FSIM:BAL:TOP:SSB
Cancel
Returns to the softkey display screen one level higher.
Port3 (bal)
*2
Displays softkeys for selecting the analyzer ports (test ports) to which (balanced) port 3 on the DUT will be
connected. This key will be displayed only when
SE-SE-Bal in the Device menu is selected.
1-2 Selects test ports 1 and 2 on the analyzer for connection with (balanced)
port 3 on the DUT (ports c and d in Table 7-8 on page 296) respectively.
:CALC{1-16}:FSIM:BAL:TOP:SSB
1-3
Selects test ports 1 and 3 on the analyzer for connection with (balanced)
port 3 on the DUT (ports c and d in Table 7-8 on page 296) respectively.
:CALC{1-16}:FSIM:BAL:TOP:SSB
1-4
Selects test ports 1 and 4 on the analyzer for connection with (balanced)
port 3 on the DUT (ports c and d in Table 7-8 on page 296) respectively.
:CALC{1-16}:FSIM:BAL:TOP:SSB
2-1
Selects test ports 2 and 1 on the analyzer for connection with (balanced)
port 3 on the DUT (ports c and d in Table 7-8 on page 296) respectively.
:CALC{1-16}:FSIM:BAL:TOP:SSB
2-3
Selects test ports 2 and 3 on the analyzer for connection with (balanced)
port 3 on the DUT (ports c and d in Table 7-8 on page 296) respectively.
:CALC{1-16}:FSIM:BAL:TOP:SSB
2-4
Selects test ports 2 and 4 on the analyzer for connection with (balanced)
port 3 on the DUT (ports c and d in Table 7-8 on page 296) respectively.
:CALC{1-16}:FSIM:BAL:TOP:SSB
3-1
Selects test ports 3 and 1 on the analyzer for connection with (balanced)
port 3 on the DUT (ports c and d in Table 7-8 on page 296) respectively.
:CALC{1-16}:FSIM:BAL:TOP:SSB
3-2
Selects test ports 3 and 2 on the analyzer for connection with (balanced)
port 3 on the DUT (ports c and d in Table 7-8 on page 296) respectively.
:CALC{1-16}:FSIM:BAL:TOP:SSB
3-4
Selects test ports 3 and 4 on the analyzer for connection with (balanced)
port 3 on the DUT (ports c and d in Table 7-8 on page 296) respectively.
:CALC{1-16}:FSIM:BAL:TOP:SSB
4-1
Selects test ports 4 and 1 on the analyzer for connection with (balanced)
port 3 on the DUT (ports c and d in Table 7-8 on page 296) respectively.
:CALC{1-16}:FSIM:BAL:TOP:SSB
4-2
Selects test ports 4 and 2 on the analyzer for connection with (balanced)
port 3 on the DUT (ports c and d in Table 7-8 on page 296) respectively.
:CALC{1-16}:FSIM:BAL:TOP:SSB
Key Operation Function SCPI Command