User`s manual

Agilent E8462A Relay Multiplexer Command Reference 93
Parameters
Comments Select MODE with [ROUTe:]FUNCtion command. The ROUT:FUNC
command is used to select the mode for the Agilent E8462A module. The
interpretation of the channel_list as to which relays will open or close depends upon
the selected mode.
One-Wire Modes (WIRE1, WIRE1X2, WIRE1X4 and WIRE1X8):
One-wire by 1 MUX, 2 MUXs, 4 MUXs or 8 MUXs. The Agilent E8462A uses
double-pole relays and a control relay is used to obtain one-wire capability. A
different channel will appear if you change the position of the control relay. Only
Parameter
Name
Parameter
Type Mode Range of Values
channel_list
numeric WIRE1
WIRE2
WIRE3
WIRE4
cc0000 to cc0255
cc0000 to cc0127
cc0000 to cc0063
cc0000 to cc0063
WIRE1X2 cc0000 to cc0127
cc1000 to cc1127
WIRE2X2 cc0000 to cc0063
cc1000 to cc1063
WIRE4X2 cc0000 to cc0031
cc1000 to cc1031
WIRE1X4 cc0000 to cc0063
cc1000 to cc1063
cc2000 to cc2063
cc3000 to cc3063
channel_list
numeric WIRE2X4 cc0000 to cc0031
cc1000 to cc1031
cc2000 to cc2031
cc3000 to cc3031
WIRE4X4 cc0000 to cc0015
cc1000 to cc1015
cc2000 to cc2015
cc3000 to cc3015
WIRE1X8 cc0000 to cc0031
cc1000 to cc1031
cc2000 to cc2031
cc3000 to cc3031
cc4000 to cc4031
cc5000 to cc5031
cc6000 to cc6031
cc7000 to cc7031
WIRE2X8 cc0000 to cc0015
cc1000 to cc1015
cc2000 to cc2015
cc3000 to cc3015
cc4000 to cc4015
cc5000 to cc5015
cc6000 to cc6015
cc7000 to cc7015
NONE cc0000 to cc0015
cc1000 to cc1015
cc2000 to cc2015
cc3000 to cc3015
cc4000 to cc4015
cc5000 to cc5015
cc6000 to cc6015
cc7000 to cc7015