User`s manual

76 Agilent E8462A Relay Multiplexer Command Reference
DIAGnostic:INTerrupt:TIMer
DIAGnostic:INTerrupt:TIMer <card_number>, <time> sets the multiplexer
interrupt timer. The <card_number> parameter specifies which module to set.
Parameters
Comments The time specified in the command will be rounded to 0.002, 0.005, 0.008 or
0.064 seconds.
Note Setting the interrupt time too small can cause system problems.
The module’s interrupt timer will be set to the specified value. This is the
amount of time the module will wait after a relay close or open command is
given before sending an interrupt and clearing the “busy” bit.
*RST does not change the selected time.
Example Delay the interrupt signal 8 mS after a relay is opened or closed.
DIAG:INT:TIM 2,0.008
Interrupt timer on card number 2 is set for
8 mS . Interrupt signal is delayed 8 mS
after an open or close to allow for settling
of relay contacts.
DIAGnostic:INTerrupt:TIMer?
DIAGnostic:INTerrupt:TIMer? <card_number> queries the specified multiplexer
module and returns the interrupt delay time.
Example Query the interrupt timer setting.
DIAG:INT:TIM? 2
Query the interrupt timer setting on card
number 2.
Name Type Range of Values Default
<card_number> numeric 1-99 1
<time> numeric 0.002 - 0.064
(0.002, 0.005, 0.008 or 0.064)
0.005 seconds